09.06.2014 Views

SERVICE MANUAL - O. Rensch OHG

SERVICE MANUAL - O. Rensch OHG

SERVICE MANUAL - O. Rensch OHG

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

(1) Interlock switch<br />

The interlock switch is located on the high voltage board and opened and closed in conjunction with the front cover or the<br />

front top cover via the interlock lever. This switch connects and disconnects the +24 V DC power supply line. If the front<br />

cover or the front top cover is open, the interlock switch is open, and the +24 V DC to the high voltage output circuit, bias<br />

board, engine board, and the power supply board is disconnected, deactivating the high voltage output, laser output, main<br />

motor output for safety. The cooling fan is an exception: Since the cooling fan is directly fed with +24 V DC from the power<br />

supply unit at the primary side (+24V1) of the interlock switch, the cooling fan is not deactivated even the cover is open.<br />

2DC<br />

Front top cover<br />

Projection<br />

Interlock lever<br />

Projection<br />

Engine board,<br />

Bias board,<br />

etc.<br />

Power supply unit<br />

+24V2<br />

Front cover<br />

+24V2<br />

Triac, etc.<br />

+24V2<br />

High voltage<br />

output circuit<br />

Interlock<br />

switch<br />

+24V2<br />

+24 V DC<br />

output<br />

+24V1<br />

+24V1<br />

Machine left side view<br />

Cooling fan<br />

High voltage board<br />

Figure 2-3-10 Interlock switch<br />

2-3-11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!