2DC<br />

3. Remove two screws and then remove two grounding plates.<br />

4. Remove the one stopper ring and then detach the scanner shaft.<br />

* Detach the shaft taking care to tilt it as little as possible.<br />

Screw<br />

Stopper ring<br />

Screw<br />

Grounding plates<br />

Scanner shaft<br />

Figure 1-6-37 Detaching the scanner shaft<br />

5. Remove the flexible flat cable from the ISU<br />

board’s connector.<br />

6. Remove the scanner belt from the belt hook<br />

of scanner unit.<br />

7. Remove the ISU unit from the scanner shaft.<br />

* Remove the ISU unit taking care not to lose<br />

the M4 nut located in the ISU unit.<br />

M4 nut<br />

Scanner unit<br />

Belt hook<br />

Scanner belt<br />

ISU board<br />

Scanner shaft<br />

Flexible flat cable<br />

ISU unit<br />

Figure 1-6-38 Removing the ISU unit<br />

1-6-33