2DC<br />

1-6-11 Removing the laser scanner unit and the eraser lamp<br />

1. Remove the scanner unit (See page 1-6-27).<br />

2. Remove each two screws and then remove<br />

two grounding plates.<br />

3. Remove each two screws and then remove<br />

the right and left scanner stays.<br />

Screws<br />

Left scanner stay<br />

Screws<br />

Grounding plates<br />

Right scanner stay<br />

Screws<br />

Figure 1-6-31 Removing the right and left stays<br />

4. Remove four connectors.<br />

5. Remove six screws and then remove the LSU<br />

shield.<br />

* When refitting the LSU shield, tighten a<br />

screw in order of 4 from 1.<br />

Screws<br />

4<br />

Screw<br />

LSU shield<br />

3<br />

2<br />

1<br />

Screws<br />

Connectors<br />

Screw<br />

Figure 1-6-32 Removing the LSU shield<br />

1-6-29