<strong>RJ</strong> <strong>Series</strong> <strong>Slim</strong> <strong>Power</strong> <strong><strong>Relay</strong>s</strong><br />
Electrical Life Curve<br />
• <strong>RJ</strong>1 (resistive load)<br />
1000<br />
• <strong>RJ</strong>2 (resistive load)<br />
1000<br />
Life (× 10,000 operations)<br />
100<br />
10<br />
30V DC Resistive Load<br />
(NO Contact)<br />
250V AC Resistive Load<br />
(NO contact)<br />
Life (× 10,000 operations)<br />
100<br />
10<br />
30V DC Resistive Load<br />
(NO Contact)<br />
250V AC Resistive Load<br />
(NO contact)<br />
1<br />
0.1 1<br />
12<br />
Load Current (A)<br />
1<br />
0.1 1 8<br />
Load Current (A)<br />
Maximum Switching Capacity<br />
• <strong>RJ</strong>1 (resistive load)<br />
• <strong>RJ</strong>2 (resistive load)<br />
AC Resistive (NO Contact)<br />
Load Current (A)<br />
12<br />
10<br />
1<br />
Load Current (A)<br />
10<br />
8<br />
1<br />
AC Resistive (NO Contact)<br />
DC Resistive (NO Contact)<br />
0.1<br />
1 10 100 250<br />
Load Voltage (V)<br />
DC Resistive (NO Contact)<br />
0.1<br />
1 10 100 250<br />
Load Voltage (V)<br />
Operating Temperature and Coil Temperature Rise<br />
• <strong>RJ</strong>1<br />
Temperature Rise (°C)<br />
• <strong>RJ</strong>2<br />
Temperature Rise (°C)<br />
AC Coil (60 Hz)<br />
130<br />
120<br />
110<br />
100<br />
90<br />
80<br />
Load Current 12A × 1 pole<br />
70<br />
60<br />
50<br />
40<br />
30 No Load Current<br />
20<br />
10<br />
130<br />
120<br />
110<br />
100<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
0 10 20 30 40 50 60 70<br />
0<br />
Ambient Temperature (°C)<br />
AC Coil (60 Hz)<br />
Load Current 8A × 2 poles<br />
10<br />
No Load Current<br />
20<br />
30<br />
40<br />
50<br />
60<br />
Ambient Temperature (°C)<br />
70<br />
Temperature Rise (°C)<br />
Temperature Rise (°C)<br />
AC Coil (50 Hz)<br />
130<br />
120<br />
110<br />
100<br />
90<br />
80<br />
Load Current 12A × 1 pole<br />
70<br />
60<br />
50<br />
40<br />
30 No Load Current<br />
20<br />
10<br />
0 10 20 30 40 50 60 70<br />
Ambient Temperature (°C)<br />
AC Coil (50 Hz)<br />
130<br />
120<br />
110<br />
100<br />
90<br />
80<br />
70 Load Current 8A × 2 poles<br />
60<br />
50<br />
40<br />
30 No Load Current<br />
20<br />
10<br />
0 10 20 30 40 50 60 70<br />
Ambient Temperature (°C)<br />
The above temperature rise curves show characteristics when 100% the rated coil voltage is applied.<br />
The slanted dashed line indicates allowable temperature rise for the coil at different ambient temperatures.<br />
Temperature Rise (°C)<br />
Temperature Rise (°C)<br />
DC Coil<br />
130<br />
120<br />
110<br />
100<br />
90<br />
80<br />
70<br />
60<br />
Load Current 12A × 1 pole<br />
50<br />
40<br />
30<br />
20<br />
No Load Current<br />
10<br />
0<br />
0 10 20 30 40 50 60 70<br />
Ambient Temperature (°C)<br />
DC Coil<br />
130<br />
120<br />
110<br />
100<br />
90<br />
80<br />
70<br />
60<br />
50<br />
Load Current 8A × 2 poles<br />
40<br />
30<br />
20 No Load Current<br />
10<br />
10 20 30 40 50 60<br />
Ambient Temperature (°C)<br />
70<br />
7