09.06.2014 Views

RJ Series Slim Power Relays SJ Series Relay ... - REM-Technik sro

RJ Series Slim Power Relays SJ Series Relay ... - REM-Technik sro

RJ Series Slim Power Relays SJ Series Relay ... - REM-Technik sro

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>RJ</strong> <strong>Series</strong> <strong>Slim</strong> <strong>Power</strong> <strong><strong>Relay</strong>s</strong><br />

Electrical Life Curve<br />

• <strong>RJ</strong>1 (resistive load)<br />

1000<br />

• <strong>RJ</strong>2 (resistive load)<br />

1000<br />

Life (× 10,000 operations)<br />

100<br />

10<br />

30V DC Resistive Load<br />

(NO Contact)<br />

250V AC Resistive Load<br />

(NO contact)<br />

Life (× 10,000 operations)<br />

100<br />

10<br />

30V DC Resistive Load<br />

(NO Contact)<br />

250V AC Resistive Load<br />

(NO contact)<br />

1<br />

0.1 1<br />

12<br />

Load Current (A)<br />

1<br />

0.1 1 8<br />

Load Current (A)<br />

Maximum Switching Capacity<br />

• <strong>RJ</strong>1 (resistive load)<br />

• <strong>RJ</strong>2 (resistive load)<br />

AC Resistive (NO Contact)<br />

Load Current (A)<br />

12<br />

10<br />

1<br />

Load Current (A)<br />

10<br />

8<br />

1<br />

AC Resistive (NO Contact)<br />

DC Resistive (NO Contact)<br />

0.1<br />

1 10 100 250<br />

Load Voltage (V)<br />

DC Resistive (NO Contact)<br />

0.1<br />

1 10 100 250<br />

Load Voltage (V)<br />

Operating Temperature and Coil Temperature Rise<br />

• <strong>RJ</strong>1<br />

Temperature Rise (°C)<br />

• <strong>RJ</strong>2<br />

Temperature Rise (°C)<br />

AC Coil (60 Hz)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

Load Current 12A × 1 pole<br />

70<br />

60<br />

50<br />

40<br />

30 No Load Current<br />

20<br />

10<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0 10 20 30 40 50 60 70<br />

0<br />

Ambient Temperature (°C)<br />

AC Coil (60 Hz)<br />

Load Current 8A × 2 poles<br />

10<br />

No Load Current<br />

20<br />

30<br />

40<br />

50<br />

60<br />

Ambient Temperature (°C)<br />

70<br />

Temperature Rise (°C)<br />

Temperature Rise (°C)<br />

AC Coil (50 Hz)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

Load Current 12A × 1 pole<br />

70<br />

60<br />

50<br />

40<br />

30 No Load Current<br />

20<br />

10<br />

0 10 20 30 40 50 60 70<br />

Ambient Temperature (°C)<br />

AC Coil (50 Hz)<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

70 Load Current 8A × 2 poles<br />

60<br />

50<br />

40<br />

30 No Load Current<br />

20<br />

10<br />

0 10 20 30 40 50 60 70<br />

Ambient Temperature (°C)<br />

The above temperature rise curves show characteristics when 100% the rated coil voltage is applied.<br />

The slanted dashed line indicates allowable temperature rise for the coil at different ambient temperatures.<br />

Temperature Rise (°C)<br />

Temperature Rise (°C)<br />

DC Coil<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

70<br />

60<br />

Load Current 12A × 1 pole<br />

50<br />

40<br />

30<br />

20<br />

No Load Current<br />

10<br />

0<br />

0 10 20 30 40 50 60 70<br />

Ambient Temperature (°C)<br />

DC Coil<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

70<br />

60<br />

50<br />

Load Current 8A × 2 poles<br />

40<br />

30<br />

20 No Load Current<br />

10<br />

10 20 30 40 50 60<br />

Ambient Temperature (°C)<br />

70<br />

7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!