79 Revised 7/22/09 (Gentry/Ranallo)<br />

Neck: Routine<br />

Adult – Angled Axials<br />

Non-Contrast or Contrast<br />

<strong>CT</strong> 1 <strong>CT</strong> 2 <strong>CT</strong> 3 <strong>CT</strong> 4 & ER <strong>CT</strong> East & RP <strong>CT</strong><br />

Scanner GE LS Xtra GE LS 16 GE LS 16 Pro GE LS V<strong>CT</strong> 64 GE LS 8<br />

Scan Type Axial Axial Axial Axial Axial<br />

Rotation Time (sec) 0.7 0.8 0.5 0.5 0.8<br />

Detector Coverage (mm)<br />

Beam Collimation (mm)<br />

10 10 10 10 10<br />

Detector Rows 16 16 16 16 8<br />

Number <strong>of</strong> Images per<br />

Rotation<br />

4i 4i 4i 4i 4i<br />

Detector Configuration 16 x 0.625 16 x 0.625 16 x 0.625 16 x 0.625 8 x 1.25<br />

Slice Thickness (mm) 2.5 2.5 2.5 2.5 2.5<br />

Scan FOV Head Head Head Head Head<br />

kV 120 120 120 120 120<br />

mA 640 440 720 720 440<br />

Recon 1:<br />

DFOV 22 22 22 22 22<br />

Recon Type Standard Standard Standard Standard Standard<br />

WW/ WL 300/35 300/35 300/35 300/35 300/35<br />

Recon 2:<br />

DFOV 22 22 22 22 22<br />

Recon Type Bone Plus Bone Plus Bone Plus Bone Plus Bone Plus<br />

WW/ WL 2500/250 2500/250 2500/250 2500/250 2500/250<br />

Slice Thickness (mm) 1.25 1.25 1.25 1.25 1.25<br />

Neck: Routine<br />

Pediatric Child (3 – 6 yr) – Angled Axials<br />

Non-Contrast or Contrast<br />

<strong>CT</strong> 1 <strong>CT</strong> 2 <strong>CT</strong> 3 <strong>CT</strong> 4 & ER <strong>CT</strong> East & RP <strong>CT</strong><br />

Scanner GE LS Xtra GE LS 16 GE LS 16 Pro GE LS V<strong>CT</strong> 64 GE LS 8<br />

Scan Type Axial Axial Axial Axial Axial<br />

Rotation Time (sec) 0.7 0.8 0.5 0.5 0.8<br />

Detector Coverage (mm)<br />

Beam Collimation (mm)<br />

10 10 10 10 10<br />

Detector Rows 16 16 16 16 8<br />

Number <strong>of</strong> Images per<br />

Rotation<br />

4i 4i 4i 4i 4i<br />

Detector Configuration 16 x 0.625 16 x 0.625 16 x 0.625 16 x 0.625 8 x 1.25<br />

Slice Thickness (mm) 2.5 2.5 2.5 2.5 2.5<br />

Scan FOV Head Head Head Head Head<br />

kV 100 100 100 100 100<br />

mA 630 420 700 700 420<br />

Recon 1:<br />

DFOV 22 22 22 22 22<br />

Recon Type Standard Standard Standard Standard Standard<br />

WW/ WL 300/35 300/35 300/35 300/35 300/35<br />

Recon 2:<br />

DFOV 22 22 22 22 22<br />

Recon Type Bone Plus Bone Plus Bone Plus Bone Plus Bone Plus<br />

WW/ WL 2500/250 2500/250 2500/250 2500/250 2500/250<br />

Slice Thickness (mm) 1.25 1.25 1.25 1.25 1.25