16 Revised 7/22/09 (Gentry/Ranallo)<br />

Head: Helical<br />

Pediatric Infant (0– 3 yr)<br />

Non-Contrast or Contrast<br />

<strong>CT</strong> 1 <strong>CT</strong> 2 <strong>CT</strong> 3 <strong>CT</strong> 4 & ER <strong>CT</strong> East & RP <strong>CT</strong><br />

Scanner GE LS Xtra GE LS 16 GE LS 16 Pro GE LS V<strong>CT</strong> 64 GE LS 8<br />

Scan Type Helical Helical Helical Helical Helical<br />

Rotation Time (sec) 0.5 0.7 0.4 0.4 0.8<br />

Detector Coverage (mm)<br />

Beam Collimation (mm)<br />

10 10 10 20 10<br />

Detector Rows 16 16 16 16 8<br />

Pitch 0.562 0.562 0.562 0.531 0.625<br />

Speed (mm/rot) 5.625 5.625 5.625 10.62 6.25<br />

Detector Configuration 16 x 0.625 16 x 0.625 16 x 0.625 64 x 0.625 8 x 1.25<br />

Slice Thickness (mm) 2.5 2.5 2.5 2.5 2.5<br />

Interval (mm) 1.5 1.5 1.5 1.5 1.5<br />

Scan FOV Head Head Head Small Head Head<br />

kV 80 80 80 80 80<br />

Smart mA/ Auto mA Range 140-675 80-390 140-675 130-640 80-390<br />

Noise Index 3.3 3.3 3.3 3.3 3.3<br />

(Manual mA) 460 260 460 430 260<br />

Recon 1:<br />

DFOV 20 20 20 20 20<br />

Recon Type Standard Standard Standard Standard Standard<br />

WW/ WL 80/25 80/25 80/25 80/25 80/25<br />

Recon Option Plus Plus Plus Plus Plus<br />

Recon 2:<br />

DFOV 20 20 20 20 20<br />

Recon Type Bone Plus Bone Plus Bone Plus Bone Plus Bone Plus<br />

WW/ WL 3000/300 3000/300 3000/300 3000/300 3000/300<br />

Recon Option Full Full Full Full Full<br />

Slice Thickness (mm) 2.5 2.5 2.5 2.5 2.5<br />

Interval (mm) 1.25 1.25 1.25 1.25 1.25