P R O D U C T<br />

SPECIFICATION FOR<br />

T R I P L E - B L E N D<br />

O D O R C O N T R O L M E D I A<br />

T R I P L E - B L E N D O D O R C O N T R O L M E D I A removes the widest variety of <strong>odor</strong>s<br />

and gases from municipal and wastewater applications. Triple-Blend Odor Control<br />

Media contains a 50:25:25 <strong>blend</strong>, respectively of Odorcarb Ultra,<br />

Odoroxidant SP and Odorkol engineered dry-chemical <strong>media</strong>. This unique<br />

combination of <strong>Purafil</strong> <strong>media</strong> formulations removes common gases found in<br />

municipal applications such as hydrogen sulfide, nitrogen dioxide, nitric oxide, sulfur<br />

dioxide, organic acids, volatile organic compounds (VOCs) as well as lower molecular<br />

weight aldehydes and hydrocarbons.<br />

w w w. p u ra f i l . c o m<br />

FIRST<br />

IN CLEAN<br />

AIR<br />

TRIPLE-BLEND<br />

MEDIA<br />

M E D I A S P E C I F I C A T I O N<br />

Triple-Blend Odor Control Media shall consist of<br />

a mix of Odoroxidant SP <strong>media</strong>, Odorkol<br />

activated carbon <strong>media</strong> and Odorcarb Ultra<br />

<strong>media</strong>.<br />

Odoroxidant SP Media shall consist of<br />

manufactured, generally spherical, porous<br />

pellets. Pellets shall be formed from a<br />

combination of activated alumina and other<br />

binders, suitably impregnated with sodium<br />

permanganate to provide optimum adsorption,<br />

absorption and oxidation of a wide variety of<br />

gaseous contaminants. The sodium<br />

permanganate shall be applied during pellet<br />

formation, such that the impregnant is uniformly<br />

distributed throughout the pellet volume and is<br />

totally available for reaction.<br />

The Odorkol Media shall be an activated carbon<br />

for the <strong>control</strong> of hydrocarbons with a high<br />

surface area available for adsorption.<br />

The Odorcarb Ultra Media, an activated aluminabased<br />

<strong>media</strong>, is formed from a combination of of<br />

powdered activated carbon, alumina, binders<br />

and reactive components for the removal of<br />

hydrogen sulfide. This <strong>media</strong> contains Media Life<br />

Indicator Pellets which offer a visual indication of<br />

remaining <strong>media</strong> life, by changing from blue to<br />

white when the <strong>media</strong> is spent.<br />

T H E C H E M I S O R P T I V E P R O C E S S<br />

The <strong>Purafil</strong> chemisorptive process shall remove<br />

contaminant gases by means of adsorption,<br />

absorption, and chemical reaction. Gases shall<br />

be trapped within the pellet where oxidation<br />

changes the gases into harmless solids,<br />

eliminating the possibility of desorption.<br />

P H Y S I C A L P R O P E R T I E S<br />

Triple-Blend Odor Control Media is a 50:25:25<br />

<strong>blend</strong>, respectively, of Odorcarb Ultra,<br />

Odoroxidant SP and Odorkol <strong>media</strong>. The overall<br />

bulk density of this Odor Control Media is<br />

40 lbs/ft 3 +5%.<br />

ODOROXIDANT SP MEDIA<br />

• BULK DENSITY: 50 lbs/ft 3 (0.8 g/cc) +5%<br />

• MOISTURE CONTENT: 35% Maximum<br />

• CRUSH STRENGTH: 35% - 70%<br />

• ABRASION: 4.5% Maximum<br />

• NOMINAL PELLET DIAMETER: 1/8"<br />

(3.175 mm)<br />

• SODIUM PERMANGANATE CONTENT:<br />

12% Minimum<br />

ODORCARB ULTRA MEDIA<br />

• MOISTURE CONTENT: 35% Maximum<br />

• CRUSH STRENGTH: 35% - 70%<br />

• ABRASION: 4.5% Maximum<br />

• NOMINAL PELLET DIAMETER: 1/8"<br />

(3.175 mm)<br />

ODORKOL MEDIA<br />

• BULK DENSITY: 30 lbs/ft 3<br />

(0.48 g/cc) +5%<br />

• MOISTURE CONTENT: 2%<br />

• CTC: 60% Minimum<br />

• NOMINAL PELLET DIAMETER: 1/8"<br />

(3.175 mm)<br />

• BASE MATERIAL: Activated carbon<br />

A P P L I C A T I O N G U I D E L I N E S<br />

Triple-Blend Odor Control Media shall perform<br />

effectively under the following conditions and<br />

guidelines:<br />

• TEMPERATURE: -4° F to 125° F<br />

(-20° C to 51° C)<br />

• HUMIDITY: 10 - 95% RH<br />

• AIRFLOW: Triple-Blend Odor Control Media<br />

shall be effective in municipal applications with<br />

airflows ranging from less than 25CFM (42.5<br />

m 3 /hr) to over 100,000 CFM (169,920 m 3 /hr)<br />

and with velocities from 60 FPM to 500 FPM<br />

(0.30 to 2.54 m/s).<br />

• MEDIA PERFORMANCE: Triple-Blend Odor<br />

Control Media shall be designed for 95%<br />

minimum removal efficiency in <strong>Purafil</strong> systems.<br />

• MEDIA LIFE: Regular <strong>media</strong> samples of<br />

Triple-Blend Odor Control Media shall be taken<br />

for projecting remaining <strong>media</strong> life, providing<br />

scheduled maintenance, and ensuring<br />

performance.<br />

<strong>Purafil</strong>, Inc. • 2654 Weaver Way, Doraville, Georgia, 30340, U.S.A. • www.purafil.com • tel: (770) 662-8545 • (800) 222-6367<br />

© <strong>Purafil</strong> 2012 ProdBltn - Triple Blend--02<br />

ISO 9001:2008


T R I P L E - B L E N D<br />

O D O R C O N T R O L M E D I A<br />

A D V A N TA G E S<br />

• Non-flammable and non-hazardous<br />

• UL Classified<br />

• Specifically engineered to eliminate municipal gases<br />

• Can be used in place of a multi-pass <strong>media</strong> system<br />

• Media life analysis projects remaining <strong>media</strong> life for proper maintenance and<br />

optimum <strong>media</strong> performance<br />

TA R G E T C O N TA M I N A N T S<br />

• Nitrogen dioxide<br />

• Sulfur dioxide<br />

• Hydrogen Sulfide & Mercaptans<br />

• Nitric oxide<br />

• Organic acids<br />

• Other VOCs<br />

• Lower molecular weight aldehydes and hydrocarbons<br />

I N S TA L L A T I O N & D I S P O S A L R E Q U I R E M E N T S<br />

• INSTALLATION: Installers shall use dust masks, safety goggles, and rubber gloves.<br />

• DISPOSAL: Spent Triple-Blend Odor Control Media should be disposed of<br />

according to local, state and federal guidelines.<br />

<strong>Purafil</strong>, Inc. • 2654 Weaver Way, Doraville, Georgia, 30340, U.S.A. • www.purafil.com • tel: (770) 662-8545 • (800) 222-6367<br />

© <strong>Purafil</strong> 2012 ProdBltn - Triple Blend--02<br />

ISO 9001:2008

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!