Table 2B6 – Summary of building energy code requirements and prescriptive criteria<br />
Source: <strong>BPIE</strong> survey<br />
Building code<br />
requirements<br />
Performance<br />
based<br />
requirements 1<br />
Prescriptive/element-based criteria in building codes<br />
New build<br />
Renovations<br />
New build<br />
Renovations<br />
Thermal insulation<br />
Air permeability<br />
Ventilation<br />
requirements<br />
Boiler/AC system<br />
efficiency<br />
Lighting efficiency<br />
O<strong>the</strong>r requirements<br />
AT Y Y Y Y Y Y Y Y N Summer comfort requirements<br />
BE-Wl Y Y Y N Y N Y N N Overheating indicator should not exceed<br />
17,500kh. T in<br />
must be <strong>under</strong> 26oC for 90% of year<br />
BE-Br Y Y Y N Y N Y N N in RE. K-values on global <strong>the</strong>rmal insulation of<br />
BE-Fl Y Y Y N Y N Y N N entire building. Thermal bridges<br />
BG Y Y Y Y Y Y N Y N<br />
CH Y Y Y Y Y N N Y NRE Thermal bridges, solar shading, max 80% of<br />
demand for heating & DHW covered by non-RES<br />
CY Y Y Y Y Y N N N N Solar collectors in new RE<br />
CZ Y Y Y Y Y Y N BO N T in<br />
of 20oC in winter and 27oC summer<br />
DE Y Y Y N Y Y Y Y NRE T in<br />
(20-26oC), humidity, air change rate & air<br />
velocity requirements<br />
DK Y Y Y N Y Y Y Y NRE Max T in<br />
26oC. Thermal bridges requirements<br />
EE Y Y Y Y Y Y Y Y NRE RE & office temperature requirements<br />
ES Y Y Y Y Y Y Y Y NRE Thermal comfort, T in<br />
21oC (winter), 26oC (summer),<br />
mandatory RES use (solar collectors/PVs)<br />
FI Y P Y P 2 Y Y Y BO Y Max T in<br />
applies (typically 25oC). Max CO 2<br />
concentration in indoor air.<br />
FR Y Y Y Y Y Y Y Y NRE Max T in<br />
applies based on a number of factors<br />
GR Y Y Y Y Y Y Y Y N<br />
HU Y Y Y Y Y N N N N<br />
IE Y Y Y N Y Y Y Thermal bridges<br />
IT Y Y Y Y Y Y Y Y N<br />
LT Y Y Y Y Y Y Y Y N<br />
LV Y Y N N Y Y Y N N Orientation, window size, air temperature, air<br />
humidity & air velocity, specific heat losses of<br />
whole building & per m 2<br />
MT Y N N N Y N N Y NRE Window size, glazing<br />
NL Y Y Y N Y Y Y NRE Daylight<br />
NO Y Y Y Y Y Y Y Y N Window size, <strong>the</strong>rmal bridges, ventilation fan<br />
power, heat recovery, summer/winter T in<br />
PL Y Y Y Y Y N Y Y Y Solar shading, window area<br />
PT Y Y Y Y Y Y NRE Y N Max g-value,<strong>the</strong>rmal bridge, solar<br />
collectors,cooling, DHW reqs apply<br />
RO Y N N N Y N N N N Overall <strong>the</strong>rmal coefficient g-value<br />
SE Y Y Y Y Y Y Y Y N<br />
SI Y Y Y Y 3 Y Y Y Y N Solar shading, max T in<br />
SK Y Y Y Y Y Y Y Y N Max T in<br />
, humidity & air velocity apply.<br />
UK Y Y Y Y Y Y Y Y Y<br />
<strong>Europe</strong>’s <strong>buildings</strong> <strong>under</strong> <strong>the</strong> <strong>microscope</strong> | 77