Table 2B6 – Summary of building energy code requirements and prescriptive criteria<br />

Source: <strong>BPIE</strong> survey<br />

Building code<br />

requirements<br />

Performance<br />

based<br />

requirements 1<br />

Prescriptive/element-based criteria in building codes<br />

New build<br />

Renovations<br />

New build<br />

Renovations<br />

Thermal insulation<br />

Air permeability<br />

Ventilation<br />

requirements<br />

Boiler/AC system<br />

efficiency<br />

Lighting efficiency<br />

O<strong>the</strong>r requirements<br />

AT Y Y Y Y Y Y Y Y N Summer comfort requirements<br />

BE-Wl Y Y Y N Y N Y N N Overheating indicator should not exceed<br />

17,500kh. T in<br />

must be <strong>under</strong> 26oC for 90% of year<br />

BE-Br Y Y Y N Y N Y N N in RE. K-values on global <strong>the</strong>rmal insulation of<br />

BE-Fl Y Y Y N Y N Y N N entire building. Thermal bridges<br />

BG Y Y Y Y Y Y N Y N<br />

CH Y Y Y Y Y N N Y NRE Thermal bridges, solar shading, max 80% of<br />

demand for heating & DHW covered by non-RES<br />

CY Y Y Y Y Y N N N N Solar collectors in new RE<br />

CZ Y Y Y Y Y Y N BO N T in<br />

of 20oC in winter and 27oC summer<br />

DE Y Y Y N Y Y Y Y NRE T in<br />

(20-26oC), humidity, air change rate & air<br />

velocity requirements<br />

DK Y Y Y N Y Y Y Y NRE Max T in<br />

26oC. Thermal bridges requirements<br />

EE Y Y Y Y Y Y Y Y NRE RE & office temperature requirements<br />

ES Y Y Y Y Y Y Y Y NRE Thermal comfort, T in<br />

21oC (winter), 26oC (summer),<br />

mandatory RES use (solar collectors/PVs)<br />

FI Y P Y P 2 Y Y Y BO Y Max T in<br />

applies (typically 25oC). Max CO 2<br />

concentration in indoor air.<br />

FR Y Y Y Y Y Y Y Y NRE Max T in<br />

applies based on a number of factors<br />

GR Y Y Y Y Y Y Y Y N<br />

HU Y Y Y Y Y N N N N<br />

IE Y Y Y N Y Y Y Thermal bridges<br />

IT Y Y Y Y Y Y Y Y N<br />

LT Y Y Y Y Y Y Y Y N<br />

LV Y Y N N Y Y Y N N Orientation, window size, air temperature, air<br />

humidity & air velocity, specific heat losses of<br />

whole building & per m 2<br />

MT Y N N N Y N N Y NRE Window size, glazing<br />

NL Y Y Y N Y Y Y NRE Daylight<br />

NO Y Y Y Y Y Y Y Y N Window size, <strong>the</strong>rmal bridges, ventilation fan<br />

power, heat recovery, summer/winter T in<br />

PL Y Y Y Y Y N Y Y Y Solar shading, window area<br />

PT Y Y Y Y Y Y NRE Y N Max g-value,<strong>the</strong>rmal bridge, solar<br />

collectors,cooling, DHW reqs apply<br />

RO Y N N N Y N N N N Overall <strong>the</strong>rmal coefficient g-value<br />

SE Y Y Y Y Y Y Y Y N<br />

SI Y Y Y Y 3 Y Y Y Y N Solar shading, max T in<br />

SK Y Y Y Y Y Y Y Y N Max T in<br />

, humidity & air velocity apply.<br />

UK Y Y Y Y Y Y Y Y Y<br />

<strong>Europe</strong>’s <strong>buildings</strong> <strong>under</strong> <strong>the</strong> <strong>microscope</strong> | 77