Miele Technical Diagrams - Euro Appliances
Miele Technical Diagrams - Euro Appliances
Miele Technical Diagrams - Euro Appliances
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Product Information<br />
<strong>Miele</strong> – Wall mounted cooker hoods<br />
Model number<br />
Hood type<br />
Appliance dimensions<br />
Height – extraction mode<br />
mm<br />
Height – recirculation mode<br />
mm<br />
Width<br />
mm<br />
Depth<br />
mm<br />
Net weight 1 )<br />
kg<br />
Net weight EXT 1 )<br />
kg<br />
Minimum safety distance from hob<br />
Electric hob<br />
mm<br />
Gas hob, open grill, deep-fat fryer<br />
mm<br />
Versions available<br />
Extraction<br />
Recirculation<br />
External motor<br />
Controls<br />
Light switch/with LED<br />
On/Off/with LED<br />
Sliding switch for power levels<br />
Sensor switch for power levels<br />
Plus/Minus power level control with LED<br />
Joystick controls<br />
5–15 min run on<br />
Check grease filter<br />
Check charcoal filter<br />
Features<br />
Flourescent tube lighting<br />
W<br />
Uplighters<br />
W<br />
Halogen lighting/with dimmer function<br />
W<br />
LED feature lighting<br />
Double acting radial fan<br />
Stainless steel grease filters<br />
Non return flap<br />
Sound insulation<br />
Ducting diameter<br />
mm<br />
Telescopic chimney<br />
Telescopic wall bracket<br />
Number of fan settings<br />
Including Intensive setting 2 )<br />
Automatic switch off of Intensive setting after 10 min<br />
Extraction rate per hour 3 )<br />
200 mm diameter ducting m 3<br />
150 mm diameter ducting m 3<br />
125 mm diameter ducting m 3<br />
120 mm diameter ducting m 3<br />
100 mm diameter ducting m 3<br />
Recirculation m 3<br />
Unrestricted m 3<br />
Noise level db (re1pw) 4 )<br />
200 mm diameter ducting db<br />
150 mm diameter ducting db<br />
125 mm diameter ducting db<br />
120 mm diameter ducting db<br />
100 mm diameter ducting db<br />
Recirculation<br />
db<br />
Electrical connection<br />
Length of cable (EXT in brackets)<br />
cm<br />
Voltage<br />
V<br />
Total connected load<br />
W<br />
Fuse rating<br />
A<br />
Radio/TV suppressed<br />
Mains interference suppressed<br />
Operating/Installation instructions<br />
DA 396-5 DA 399-5 DA 5495 W DA 249-4 DA 5690 W Alba<br />
Wall Wall Wall Wall Wall<br />
720–1015 720–1015 690–1000 716–966 705–1015<br />
830–1150 830–1150 805–1115 836–1066 830–1140<br />
598 898 898 900 898<br />
520 520 520 500 520<br />
21.6 24.6 26 22.5 28<br />
– – – – 25<br />
450 450 450 450 450<br />
650 650 650 650 650<br />
<br />
<br />
– – – <br />
/ / / / <br />
/ / / / –<br />
– – – – –<br />
– – – – <br />
<br />
– – – – <br />
– – – <br />
– – – <br />
– – – <br />
– – – – –<br />
– – – – –<br />
2 x 50/– 2 x 50/– 2 x 20/– 2 x 20/ 3 x 20<br />
– – – – –<br />
<br />
2 4 2 1 + 1 3<br />
<br />
– – – – <br />
125/150 125/150 125/150 125/150 125/150<br />
<br />
– – – – <br />
4 4 4 4 4<br />
<br />
– – <br />
– – – – –<br />
150–500 150–500 150–500 200–640 200/400/640<br />
130–450 130–450 130–450 180–580 180/380/580<br />
– – – – –<br />
– – – – –<br />
100–350 100–350 100–350 150–490 150/330/490<br />
500 500 500 640 640<br />
– – – – –<br />
41–61 41–61 41–61 41–66 40/53/65<br />
42–62 42–62 42–62 42–67 41/54/66<br />
– – – – –<br />
– – – – –<br />
48–67 48–67 48–67 52–72 51/65/72<br />
150 150 150 150 (190) 150 (190)<br />
230 230 230 230 230<br />
220 220 160 240 260<br />
5 5 5 5 5<br />
<br />
<br />
<br />
= standard feature<br />
1 ) Take care to ensure that the unit or wall can bear the weight of the appliance<br />
2 ) Short term higher extraction performance, accompanied by higher noise level<br />
3 ) Air throughput according to EN 61591. For EXT models the connected load and extraction power will vary depending on the type of external motor fitted<br />
4 ) Noise levels measured in acc. with EN 60704-2-13 and EN 60704-3<br />
N.B. These appliances conform to <strong>Euro</strong>pean safety regulations and must be installed in accordance with IEE regulations by a competent person<br />
124