Power supplies SITOP power LOGO!Power Catalog K T 10.1 2004
Power supplies SITOP power LOGO!Power Catalog K T 10.1 2004 Power supplies SITOP power LOGO!Power Catalog K T 10.1 2004
SITOP power AS interface power supplies Single-phase AS interface power supplies, stabilized ■ Overview The IP65 version The IP20 version ■ Application The AS interface power supply unit with IP65 degree of protection for any mounting position is particularly suitable for use in extremely harsh environments. Thanks to the 24 V DC input voltage it is ideally suitable for use together with a proven SITOP power 24 V standard power supply unit. This AS interface power supply unit with its wide-range input of 93 to 264 V AC and 110 to 350 V DC can be universally used in all typical power supply networks. With limitation of the input current harmonics acc. to EN 61000-3-2; with SIMATIC S7-300 design. 11 ■ Technical specifications Power supply, type 2.4 A 7 A Order No. 6EP1 632-1AL01 6EP1 354-1AL01 Input DC voltage Single-phase AC Rated voltage V in rated 24 V DC 120 to 230 V AC wide-range input Voltage range 20.4 to 28.8 V DC 93 to 264 V AC/110 to 350 V DC Overvoltage strength 35 V DC for max. 500 ms 2.3 x V in rated , 1.3 ms Mains buffering at I out rated > 10 ms > 20 ms at V in = 93/187 V Rated line frequency; range - 0/50/60 Hz; 47 to 63 Hz Rated input current I in rated 3.6 A 2.2 to 1.2 A Inrush current limitation (+25 °C) - < 20 A, < 3 ms I 2 t - < 1.5 A 2 s Integrated line-side fuse T 6.3 A (not accessible) T 6.3 A (not accessible) Recommended circuit-breaker From 10 A, Characteristic C or From 16 A, Characteristic C (IEC 898) in mains supply line from 6 A, Characteristic D Output Continued on page 11/3. Stabilized, floating direct voltage acc. to AS interface specifications Rated voltage V out rated 30 V DC 30 V DC Stabilized, floating direct voltage acc. to AS interface specification Total tolerance 29.5 V to 31.6 V DC 29.5 to 31.6 V DC Residual ripple < 300 mV pp < 300 mV pp Spikes < 50 mV pp < 50 mV pp Status display Green LED Green LED Rated current I out rated 2.4 A 7 A Efficiency / power loss Efficiency at V out rated , I out rated > 81% > 85% Power loss at V out rated , I out rated < 17 W < 37 W Protection and monitoring functions Output overvoltage protection - Yes Current limiting From approx. 2.9 A From approx. 7.4 A Short-circuit protection Constant current characteristic approx. 2.9 A Constant current characteristic approx. 7.4 A 11/2 Siemens KT10.1 · 2004
Power supply, type 2.4 A 7 A Order No. 6EP1 632-1AL01 6EP1 354-1AL01 Safety Galvanic isolation primary/secondary Yes, SELV output voltage V out acc. to EN 60950 Protective class Class I Class I Degree of protection (EN 60529) IP65 1) IP20 CE marking Yes Yes UL/cUL (CSA) approval UL (UL 508), File 179336, CSA (CSA 22.2 No. 14-95) SITOP power AS interface power supplies Single-phase AS interface power supplies, stabilized Yes, SELV output voltage V out acc. to EN 60950 cULus (UL 508, CSA 22.2 No.14-M91), File E143289 EMC Interference emission EN 55022 Class B EN 55022 Class B Line harmonics limitation Not applicable EN 61000-3-2 Interference immunity EN 61000-6-2 EN 61000-6-2 Operating specifications Ambient temperature range -25 to +55 °C 0 to +55 °C Transportation and storage -25 to +85 °C -25 to +85 °C temperature range Humidity rating Mechanical specifications Input connections Climatic class 3K3 acc. to EN 60721, no condensation Climatic class 3K3 acc. to EN 60721, no condensation Circular connector 0.5 to One screw-type terminal each 2.5 mm 21)2) for 0.5 to 2.5 mm 2 singlecore/finely stranded Output connections AS i + Output connections AS i - Output connections Ground 500 mm three-core cable AWG 14 1) 500 mm three-core cable AWG 14 1) 500 mm three-core cable AWG 14 1) 3 screw-type terminals for 0.5 to 2.5 mm 2 3 screw-type terminals for 0.5 to 2.5 mm 2 2 screw-type terminals for 0.5 to 2.5 mm 2 Dimensions (W x H x D) in mm 224 x 80 x 57 200 x 125 x 135 Weight approx. 1.0 kg 1.8 kg Mounting Wall mounting, any mounting position Snap-mounting on DIN rail EN 50022-35x15 mm and S7 rail Accessories 6-pin circular input connector (6ES5 760-2CA11) and AS interface coupling module PG (3RG9 220-0AA00) - 11 1) In IP20 degree of protection with screw-type terminals on request. 2) The counterpart must be ordered separately (not included in the scope of delivery); see Accessories. Siemens KT10.1 · 2004 11/3
- Page 31 and 32: SITOP power · Standard 24 V Single
- Page 33 and 34: SITOP power · Standard 24 V Single
- Page 35 and 36: SITOP power · Standard 24 V Single
- Page 37 and 38: SITOP power · Standard 24 V Single
- Page 39 and 40: SITOP power · Standard 24 V Single
- Page 41 and 42: SITOP power · Standard 24 V Three-
- Page 43 and 44: SITOP power · Standard 24 V Three-
- Page 45 and 46: SITOP power · Standard 24 V Three-
- Page 47 and 48: SITOP power · Standard 24 V Three-
- Page 49 and 50: SITOP power · Standard 24 V Three-
- Page 51 and 52: SITOP power · Standard 24 V Additi
- Page 53 and 54: SITOP power · Standard 24 V Additi
- Page 55 and 56: SITOP power · Standard 24 V Additi
- Page 57 and 58: SITOP power · Standard 24 V Additi
- Page 59 and 60: SITOP power · Standard 24 V Uninte
- Page 61 and 62: SITOP power · Standard 24 V Uninte
- Page 63 and 64: SITOP power · Standard 24 V Uninte
- Page 65 and 66: SITOP power · Standard 24 V Uninte
- Page 67 and 68: SITOP power · Standard 24 V Uninte
- Page 69 and 70: SITOP power · Standard 24 V Uninte
- Page 71 and 72: SITOP power · Standard 24 V Uninte
- Page 73 and 74: SITOP power · Standard 24 V Uninte
- Page 75 and 76: SITOP power · Standard 24 V Uninte
- Page 77 and 78: SITOP power Alternative voltages 10
- Page 79 and 80: SITOP power Alternative voltages
- Page 81: SITOP power AS interface power supp
- Page 85 and 86: SITOP power Customized 12 12/2 Desc
- Page 87 and 88: SITOP power Customized ■ FAX repl
- Page 89 and 90: LOGO!Power 13 13/2 LOGO!Power 5 V 1
- Page 91 and 92: LOGO!Power LOGO!Power 5 V Power sup
- Page 93 and 94: LOGO!Power LOGO!Power 12 V Power su
- Page 95 and 96: LOGO!Power LOGO!Power 15 V Power su
- Page 97 and 98: LOGO!Power LOGO!Power 24 V Power su
- Page 99 and 100: Technical information and configura
- Page 101 and 102: Technical information and configura
- Page 103 and 104: Technical information and configura
- Page 105 and 106: Technical information and configura
- Page 107 and 108: Technical information and configura
- Page 109 and 110: Technical information and configura
- Page 111 and 112: Technical information and configura
- Page 113 and 114: Technical information and configura
- Page 115 and 116: Technical information and configura
- Page 117 and 118: Technical information and configura
- Page 119 and 120: Technical information and configura
- Page 121 and 122: Dimension drawings 15 SITOP power N
- Page 123 and 124: Dimension drawings SITOP power Sing
- Page 125 and 126: Dimension drawings SITOP power Sing
- Page 127 and 128: Dimension drawings SITOP power Sing
- Page 129 and 130: Dimension drawings SITOP power Addi
- Page 131 and 132: Dimension drawings SITOP power Unin
<strong>SITOP</strong> <strong>power</strong><br />
AS interface <strong>power</strong> <strong>supplies</strong><br />
Single-phase AS interface <strong>power</strong> <strong>supplies</strong>,<br />
stabilized<br />
■ Overview The IP65 version The IP20 version<br />
■ Application<br />
The AS interface <strong>power</strong> supply<br />
unit with IP65 degree of<br />
protection for any mounting<br />
position is particularly suitable<br />
for use in extremely harsh<br />
environments. Thanks to the<br />
24 V DC input voltage it is<br />
ideally suitable for use together<br />
with a proven <strong>SITOP</strong><br />
<strong>power</strong> 24 V standard <strong>power</strong><br />
supply unit.<br />
This AS interface <strong>power</strong> supply<br />
unit with its wide-range<br />
input of 93 to 264 V AC and<br />
110 to 350 V DC can be<br />
universally used in all typical<br />
<strong>power</strong> supply networks.<br />
With limitation of the input<br />
current harmonics acc. to<br />
EN 61000-3-2; with SIMATIC<br />
S7-300 design.<br />
11<br />
■ Technical specifications<br />
<strong>Power</strong> supply, type 2.4 A 7 A<br />
Order No. 6EP1 632-1AL01 6EP1 354-1AL01<br />
Input DC voltage Single-phase AC<br />
Rated voltage V in rated 24 V DC 120 to 230 V AC<br />
wide-range input<br />
Voltage range 20.4 to 28.8 V DC 93 to 264 V AC/110 to 350 V DC<br />
Overvoltage strength 35 V DC for max. 500 ms 2.3 x V in rated , 1.3 ms<br />
Mains buffering at I out rated > 10 ms > 20 ms at V in = 93/187 V<br />
Rated line frequency; range - 0/50/60 Hz; 47 to 63 Hz<br />
Rated input current I in rated 3.6 A 2.2 to 1.2 A<br />
Inrush current limitation (+25 °C) - < 20 A, < 3 ms<br />
I 2 t - < 1.5 A 2 s<br />
Integrated line-side fuse T 6.3 A (not accessible) T 6.3 A (not accessible)<br />
Recommended circuit-breaker From 10 A, Characteristic C or From 16 A, Characteristic C<br />
(IEC 898) in mains supply line from 6 A, Characteristic D<br />
Output<br />
Continued on page 11/3.<br />
Stabilized, floating direct<br />
voltage acc. to AS interface<br />
specifications<br />
Rated voltage V out rated 30 V DC 30 V DC<br />
Stabilized, floating direct<br />
voltage acc. to AS interface<br />
specification<br />
Total tolerance 29.5 V to 31.6 V DC 29.5 to 31.6 V DC<br />
Residual ripple < 300 mV pp < 300 mV pp<br />
Spikes < 50 mV pp < 50 mV pp<br />
Status display Green LED Green LED<br />
Rated current I out rated 2.4 A 7 A<br />
Efficiency / <strong>power</strong> loss<br />
Efficiency at V out rated , I out rated > 81% > 85%<br />
<strong>Power</strong> loss at V out rated , I out rated < 17 W < 37 W<br />
Protection and monitoring<br />
functions<br />
Output overvoltage protection - Yes<br />
Current limiting From approx. 2.9 A From approx. 7.4 A<br />
Short-circuit protection<br />
Constant current characteristic<br />
approx. 2.9 A<br />
Constant current characteristic<br />
approx. 7.4 A<br />
11/2<br />
Siemens KT<strong>10.1</strong> · <strong>2004</strong>