31.05.2014 Views

Power supplies SITOP power LOGO!Power Catalog K T 10.1 2004

Power supplies SITOP power LOGO!Power Catalog K T 10.1 2004

Power supplies SITOP power LOGO!Power Catalog K T 10.1 2004

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>SITOP</strong> <strong>power</strong> · Standard 24 V<br />

Uninterruptible <strong>power</strong> <strong>supplies</strong><br />

DC UPS module 40 A<br />

■ Overview<br />

• Mounting depth only approx. 65 mm<br />

• Rated output <strong>power</strong> 480 W with one battery module, 960 W with<br />

two battery modules<br />

• Extremely high efficiency of approx. 99% as result of patented<br />

circuit concept<br />

• Immediate electronic connection of battery as soon as the consumer<br />

voltage or the voltage present between the L+/M terminals<br />

of the DC UPS module falls below a value of 22.5 V DC.<br />

The consumer voltage only drops to 22 V DC for a maximum of<br />

1 ms.<br />

• High electronically limited peak currents (120 A for approx.<br />

12 ms, up to 40 A for several minutes depending on the battery<br />

capacity) are automatically delivered in the event of increased<br />

load current requirements (e.g. when switching on incandescent<br />

lamps, contactors with DC autotransformer winding,<br />

DC motors, DC/DC converters, electronic modules with high<br />

input capacitance). To achieve this, at least two battery modules<br />

of 7 Ah or more must be connected in parallel.<br />

• Following a <strong>power</strong> failure, the battery module is automatically<br />

disconnected from the consumers electronically and rapidly<br />

recharged with a constant current of 2 A (V/I characteristic with<br />

27.3 V end-of-charge voltage).<br />

• Signalling<br />

- Green LED/yellow LED and floating changeover contact for<br />

mains/battery mode<br />

- Red LED and floating changeover contact for buffer readiness<br />

(LED off)/ alarm (LED on)<br />

■ Integration<br />

Mains Main switch <strong>Power</strong> supply DC UPS module Load<br />

24 V<br />

DC UPS module 40<br />

24 V<br />

<strong>SITOP</strong> <strong>power</strong><br />

3 AC<br />

10 to 40 A<br />

Aux. contact<br />

ON/OFF<br />

Message: mains or<br />

buffer mode<br />

(floating changeover<br />

contact)<br />

Message: buffer<br />

readiness<br />

or alarm/prewarning<br />

prior to switching-off<br />

of battery<br />

9<br />

24 V battery module<br />

G_KT01_EN_00159<br />

Block diagram: Configuration of uninterruptible <strong>SITOP</strong> <strong>power</strong> supply 40 A<br />

Siemens KT<strong>10.1</strong> · <strong>2004</strong> 9/11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!