<strong>SITOP</strong> <strong>power</strong> · Standard 24 V<br />

Single-phase and two-phase<br />

Output currents 20 A and 40 A<br />

The proven type The two-phase version<br />

The tried and tested <strong>power</strong><br />

supply unit with selectable input<br />

voltage range for supplying<br />

all standard applications<br />

in automation engineering.<br />

The <strong>power</strong> supply unit with<br />

2-phase wide-range input for<br />

widely changing <strong>power</strong> supply<br />

networks (> 550 V) as well<br />

as industrial networks in<br />

Canada and the USA.<br />

6<br />

20 A 20 A<br />

6EP1 336-2BA00<br />

6EP1 536-2AA00<br />

Single-phase AC<br />

120/230 V AC<br />

Settable using wire jumper<br />

Two-phase AC<br />

500 to 600 V 2 AC<br />

wide-range input<br />

93 to 132/187 to 264 V AC 420 to 682 V 2 AC<br />

2.3 x V in rated , 1.3 ms 2.3 x V in rated , 1.3 ms<br />

> 10 ms at V in = 93/187 V 6/30 ms at V in = 420/600 V<br />

50/60 Hz, 47 to 63 Hz 50/60 Hz; 47 to 63 Hz<br />

8.0/3.3 A 1.82 A (at 420 V)<br />

< 81 A typ. 25 A<br />

< 8 A 2 s < 1.0 A 2 s<br />

T 10 A (not accessible)<br />

none<br />

Circuit-breaker from 16 A<br />

Characteristic C<br />

Required: 2-pole coupled circuit-breaker<br />

Char. C max. 10 A<br />

or motor circuit-breaker<br />

3RV1021-1DA10, setting 3 A<br />

Stabilized, floating direct voltage Stabilized, floating direct voltage<br />

24 V DC 24 V DC<br />

±3% ±3%<br />

< 150 mV pp < 150 mV pp<br />

< 240 mV pp < 240 mV pp<br />

22.8 to 26.4 V 1) 22.8 to 28.8 V 2)<br />

Green LED for 24 V O.K.<br />

Green LED for 24 V O.K.<br />

No overshoot of V out<br />

(soft start)<br />

Small overshoot of V out (< 2 V for<br />

max. 500 ms)<br />

< 3 s/typ. 80 ms -<br />

20 A 20 A<br />

0 to 20 A 0 to 20 A<br />

0 to 20 A (55 °C) 0 to 20 A<br />

Approx. 20 A constant current Approx. 25 A constant current<br />

Approx. 20 A constant current Approx. 28 A constant current<br />

Yes, 2 1) Yes, 2 2)<br />

Continued on page 6/5.<br />

1) Only permissible with ambient temperature from 0 to 45 °C.<br />

2) Only permissible with ambient temperature from 0 to 50 °C.<br />

Siemens KT<strong>10.1</strong> · <strong>2004</strong> 6/3