Power supplies SITOP power LOGO!Power Catalog K T 10.1 2004
Power supplies SITOP power LOGO!Power Catalog K T 10.1 2004
Power supplies SITOP power LOGO!Power Catalog K T 10.1 2004
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>SITOP</strong> <strong>power</strong> · Standard 24 V<br />
Single-phase and two-phase<br />
Output current 5 A<br />
■ Overview <strong>SITOP</strong> modular The proven types<br />
4<br />
■ Application<br />
The modular <strong>power</strong> supply<br />
unit with single-phase and<br />
two-phase wide-range inputs<br />
for global use in many different<br />
fields of application; expansion<br />
of functions possible<br />
using add-on modules.<br />
The tried and tested <strong>power</strong> supply unit with selectable input voltage<br />
range for supplying all standard applications in automation<br />
engineering; 6EP1333-2AA00 without limitation of input current<br />
harmonics.<br />
■ Technical specifications<br />
<strong>Power</strong> supply, type 5 A 5 A 5 A<br />
Order No. 6EP1 333-3BA00 6EP1 333-2BA00 6EP1 333-2AA00<br />
Input Single and two-phase AC Single-phase AC Single-phase AC<br />
Rated voltage V in rated<br />
120/230 to 500 V AC<br />
120/230 V AC<br />
120/230 V AC<br />
Settable via selector switch on Settable using wire jumper<br />
Settable using wire jumper<br />
device<br />
Voltage range 85 to 132 V/176 to 550 V AC 93 to 132 V/187 to 264 V AC 93 to 132 V/187 to 264 V AC<br />
Overvoltage strength 1300 V peak , 1.3 ms 2.3 x V in rated , 1.3 ms 2.3 x V in rated , 1.3 ms<br />
Mains buffering at I out rated > 25 ms at V in = 120/230 V > 10 ms at V in = 93/187 V > 20 ms at V in = 93/187 V<br />
Rated line frequency; range 50/60 Hz; 47 to 63 Hz 50/60 Hz; 47 to 63 Hz 50/60 Hz; 47 to 63 Hz<br />
Rated current I in rated 2.2 /1.2 to 0.61 A 2.2/0.9 A 2.2/1.3 A<br />
Inrush current limitation (+25 °C) < 35 A < 32 A, typ. 3 ms < 32 A, typ. 3 ms<br />
I 2 t < 1.7 A 2 s < 0.8 A 2 s < 0.8 A 2 s<br />
Integrated line-side fuse T 3, 15 A (not accessible) T 3.15 A/250 V (not accessible) T 3.15 A/250 V (not accessible)<br />
Recommended circuit-breaker<br />
From 6 A, Characteristic C<br />
From 6 A, Characteristic C<br />
(IEC 898) in mains supply line<br />
Continued on page 4/4.<br />
From 6 A (10 A) Characteristic C<br />
(B); with two-phase operation:<br />
circuit-breaker with two-pole<br />
connection or motor circuitbreaker<br />
3RV1021-1EA10<br />
Output Stabilized, floating direct voltage Stabilized, floating direct voltage Stabilized, floating direct voltage<br />
Rated voltage V out rated 24 V DC 24 V DC 24 V DC<br />
Total tolerance ± 3 % ± 3 % ± 3 %<br />
• Stat. mains compensation Approx. 0.1 % Approx. 0.1 % Approx. 0.1 %<br />
• Stat. load compensation Approx. 0.1 % Approx. 0.2 % Approx. 0.2 %<br />
Residual ripple (clock frequency: < 50 mV pp (typ. 10 mV pp ) < 150 mV pp < 150 mV pp<br />
approx. 50 kHz)<br />
Spikes (bandwidth: 20 MHz) < 200 mV pp (typ. 20 mV pp ) < 240 mV pp < 240 mV pp<br />
Setting range 24 to 28.8 V (max. 120 W) 22.8 to 26.4 V 22.8 to 26.4 V<br />
Status display Green LED for 24 V O.K. Green LED for 24 V O.K. Green LED for 24 V O.K.<br />
<strong>Power</strong> ON/OFF behavior Overshoot of V out approx. 3 % No overshoot of V out (soft start) No overshoot of V out (soft start)<br />
Starting delay/voltage rise < 1 s/< 50 ms < 3 s/typ. 80 ms < 3 s/typ. 80 ms<br />
Rated current I out rated 5 A 5 A 5 A<br />
Current range<br />
• Up to +45 °C 0 to 5 A 0 to 5 A 0 to 5 A<br />
• Up to +60 °C 0 to 5 A 0 to 5 A 0 to 5 A<br />
Dyn. V/I with<br />
• Starting on short circuit<br />
Approx. 5.5 A constant current<br />
• Short-circuit in operation typ. 15 A for 25 ms typ. 20 A for 350 ms typ. 20 A for 350 ms<br />
Parallel connection for increased<br />
output<br />
Yes, 2 (selectable current characteristic)<br />
Yes, 2 Yes, 2<br />
4/2<br />
Siemens KT<strong>10.1</strong> · <strong>2004</strong>