Land Acquisition Criteria<br />

7. If the noise generated by the development exceeds the criteria in Table 10, the<br />

Applicant shall, upon receiving a written request for acquisition from the landowner,<br />

acquire the land in accordance with the procedures in conditions 9-11 <strong>of</strong> schedule<br />

5.<br />

Day/Evening/Night<br />

L Aeq(15 minute)<br />

Property<br />

43<br />

94 - Curlewis<br />

23C – Kannar<br />

254A - Algie<br />

40 All other residential or sensitive receptor,<br />

excluding the receptors listed in condition<br />

1 above<br />

Table 10: Land acquisition criteria dB(A)<br />

Note: Noise generated by the development is to be measured in accordance with<br />

the notes presented below Table 9 above.<br />

Monitoring<br />

8. The Applicant shall conduct real-time monitoring <strong>of</strong> the noise generated by the<br />

development at a minimum <strong>of</strong> four properties to the south and north-west <strong>of</strong> the<br />

site, in general accordance with the NSW Industrial Noise Policy and AS1055-<br />

1997: Acoustics – Description and Measurement <strong>of</strong> Environmental.<br />

9. Before carrying out any development, the Applicant shall prepare a Noise<br />

Monitoring Program to the satisfaction <strong>of</strong> the Director-General, which includes a<br />

noise monitoring protocol for evaluating compliance with the criteria in tables 9 &<br />

10.<br />

3 METEOROLOGICAL MONITORING<br />

10. The Applicant shall establish a permanent meteorological station at a location<br />

approved by the DEC, and to the satisfaction <strong>of</strong> the Director-General, to monitor<br />

the parameters specified in Table 11, using the specified units <strong>of</strong> measure,<br />

averaging period, frequency, and sampling method in the table.<br />

Parameter Units <strong>of</strong><br />

measure<br />

Averaging<br />

period<br />

Frequenc<br />

y<br />

Sampling<br />

method 1<br />

Lapse rate ºC/100m 1 hour Continuou Note 2<br />

s<br />

Rainfall mm/hr 1 hour Continuou AM-4<br />

s<br />

Sigma Theta @ 10 m ° 1 hour Continuou AM-2<br />

s<br />

Siting - - - AM-1<br />

Temperature @ 10 m K 1 hour Continuou<br />

s<br />

AM-4<br />

3<br />

Incorporates DEC GTA<br />

13