Development Consent - Department of Planning
Development Consent - Department of Planning
Development Consent - Department of Planning
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Land Acquisition Criteria<br />
7. If the noise generated by the development exceeds the criteria in Table 10, the<br />
Applicant shall, upon receiving a written request for acquisition from the landowner,<br />
acquire the land in accordance with the procedures in conditions 9-11 <strong>of</strong> schedule<br />
5.<br />
Day/Evening/Night<br />
L Aeq(15 minute)<br />
Property<br />
43<br />
94 - Curlewis<br />
23C – Kannar<br />
254A - Algie<br />
40 All other residential or sensitive receptor,<br />
excluding the receptors listed in condition<br />
1 above<br />
Table 10: Land acquisition criteria dB(A)<br />
Note: Noise generated by the development is to be measured in accordance with<br />
the notes presented below Table 9 above.<br />
Monitoring<br />
8. The Applicant shall conduct real-time monitoring <strong>of</strong> the noise generated by the<br />
development at a minimum <strong>of</strong> four properties to the south and north-west <strong>of</strong> the<br />
site, in general accordance with the NSW Industrial Noise Policy and AS1055-<br />
1997: Acoustics – Description and Measurement <strong>of</strong> Environmental.<br />
9. Before carrying out any development, the Applicant shall prepare a Noise<br />
Monitoring Program to the satisfaction <strong>of</strong> the Director-General, which includes a<br />
noise monitoring protocol for evaluating compliance with the criteria in tables 9 &<br />
10.<br />
3 METEOROLOGICAL MONITORING<br />
10. The Applicant shall establish a permanent meteorological station at a location<br />
approved by the DEC, and to the satisfaction <strong>of</strong> the Director-General, to monitor<br />
the parameters specified in Table 11, using the specified units <strong>of</strong> measure,<br />
averaging period, frequency, and sampling method in the table.<br />
Parameter Units <strong>of</strong><br />
measure<br />
Averaging<br />
period<br />
Frequenc<br />
y<br />
Sampling<br />
method 1<br />
Lapse rate ºC/100m 1 hour Continuou Note 2<br />
s<br />
Rainfall mm/hr 1 hour Continuou AM-4<br />
s<br />
Sigma Theta @ 10 m ° 1 hour Continuou AM-2<br />
s<br />
Siting - - - AM-1<br />
Temperature @ 10 m K 1 hour Continuou<br />
s<br />
AM-4<br />
3<br />
Incorporates DEC GTA<br />
13