<strong>PHFA</strong> Appendix I<br />

required if the water is collected at the subject property and then run through a filtration system. If the water is supplied from a public<br />

utility that pumps the water into the storage tank, no potability test is needed.<br />

Septic certifications – are not required by <strong>PHFA</strong> unless the appraiser and/or the agreement of sale comments on a potential problem.<br />

Shared septic systems are not eligible unless they are monitored by DEP.<br />

Holding tanks – how often must the tank be emptied? This cost must be reflected in the borrower’s PITI ratios. Are holding tanks<br />

acceptable to the township? Provide a statement why the property is using a holding tank and ascertain if a regular system may be<br />

installed. The appraiser is to use comparables that use holding tanks or make the appropriate adjustments.<br />

Wildcat sewer systems – the appraiser must state if it is common to the area and what effect it may have on value and marketability.<br />

The SEO or township official must provide a statement that they are aware of this type of system and due to specific reasons (such as<br />

topography) it is acceptable and no changes are required. The appraiser is to provide at least one comparable with this type of sewage<br />

system. The borrowers are to provide a hold-harmless letter.<br />

Cesspools – the appraiser is to state if they are acceptable and common to the area. A qualified inspector must certify that the system is<br />

working properly. The appraiser should use comparables with cesspools or make appropriate adjustments.<br />

60 AMP electrical service – the appraiser is to state that this is common to the area or the service must be upgraded to 100 AMPS. If<br />

common, at least one comparable must have service less than 100 AMPS.<br />

Knob and Tube Wiring – all visible knob and tube wiring must be replaced, and a qualified electrician must provide a statement that<br />

the system is in satisfactory condition. Also, the borrower(s) must sign a statement acknowledging that they understand: (1) they cannot<br />

insulate exterior wall cavities or floor/ceiling joist spaces that contain knob and tube wiring as it could lead to fire; (2) knob and tube<br />

wiring is not grounded but grounding can be accomplished by replacing existing older receptacles connected to knob and tube wiring<br />

with GFI receptacles, or protecting the circuit with a GFI breaker.<br />

DESCRIPTION AND IMPROVEMENTS AREA:<br />

Damp basement – must be repaired unless the appraiser states that it is common to the area and will have no effect of marketability. If<br />

there is standing water in the basement the source of the problem must be identified and corrected.<br />

Settlement – needs to be addressed if the appraiser makes any derogatory comments about it.<br />

Dirt basements – must be cemented unless the appraiser states that they are common to the area and will have no effect on<br />

marketability. The mechanical systems must be on concrete slabs.<br />

Coal furnaces – verify if auto or manual fed system. If manual fed there must be a back-up heating system that provides heat to all<br />

living spaces. The appraiser is to comment if these systems are accepted and common to the area and what affect, if any, it will have on<br />

marketability.<br />

Outdoor (wood) Furnaces – Property must have a back-up heating system that provides heat to all living areas. The appraiser is to<br />

comment if these systems are accepted and common to the area and what affect, if any, it will have on value and marketability.<br />

Verification it is acceptable in the community and that there is no ordinance against their use.<br />

Unheated living spaces – ALL living areas must have a heat source - the minimum requirement is the installation of floor/wall registers.<br />

Space heaters must be vented and properly operating.<br />

Manufactured homes – single-wide homes are only eligible if FHA insured. Double-wide homes – please refer to Chapter 8 of the<br />

Seller’s Guide.<br />

Two-Unit Properties – loans can be conventional, FHA insured or VA guaranteed. Must be side-by-side or stacked on top of each<br />

other. A finished basement, attic or unit above a garage does not qualify. If the borrower(s) is using the rental income to qualify, the<br />

appraiser must complete the “Estimated Market Rent” and the “Gross Rent Multiplier” section of the appraisal.<br />

Basement kitchen/bathroom – if the only kitchen is located in the basement there must be an outside entry or the loan cannot be done<br />

as a conventional product. If the only bathroom is in the basement the loan cannot be done as a conventional product. If either of these<br />

conditions exists the loan must be under the FHA or VA program.<br />

Underground fuel/gas tanks – if the tanks are for residential heating purposes then they are acceptable. Gasoline tanks must be<br />

removed and the soil tested for contamination.<br />

“Fair” ratings on appraisal – repairs must be completed in order to upgrade the ratings to “average” or better; if the appraiser is<br />

referring to “cosmetic” items (paint, carpet, etc) repairs are not necessary.<br />

Gas wells – is the well on the subject property? If not, provide a recorded maintenance agreement and a right-of-way to the well. A<br />

back-up heating system is required and must be identified by the appraiser. Disclose the number of properties serviced by the well. Is<br />

the amount of gas produced consistent throughout the year or does it fluctuate? Provide a history of the well confirming that it is<br />

sufficient to service the number of homes stated.<br />