Q: When import the data from out exls. how to delete the unnecessary information and how to match<br />

the form <strong>WNL</strong> required?<br />

The import Wizard in Phoenix allows you to indicate the rows to import from an Excel file. I will attach<br />

the phoenix project that was partially shown in the webinar if you want to see some additional details.<br />

You will need to have Phoenix WinNonlin installed even if you don’t have license.<br />

Q: What does <strong>Pharsight</strong> recommend as calculation estimation: linear up/log down, or other?<br />

I (Ana) can only speak for myself but my opinion is that if you had to pick a default estimation the best<br />

would be the general linear up/log down because it accounts for several bumps on the data and also for<br />

log-estimation on the decay part of the curve which is especially important if the data are considerably<br />

spread out. However, with rich datasets when the data was collected relatively close to each other the<br />

4 methods will give you very similar results and one should just document what was use for<br />

reproducibility but I doubt it would change any major conclusion.<br />

Q: Why does my version number show as 1.0 on my NCA core output? Our <strong>QA</strong> Dept. is complaining<br />

that it used to be there and is not anymore!<br />

The core output for NCA still shows the core version number 1.0 (right at the beginning). This version<br />

applies to the NCA analysis engine (the “core”), which is unchanged since 2007. The NCA engine is one<br />

of many analysis engines implemented in <strong>WNL</strong>/<strong>PHX</strong> <strong>WNL</strong>. The NCA user interface has changed but the<br />

engines behind it are stable and remain the same. See screenshot<br />

However, we realize that this could be confusing so we have entered a defect to make sure that the<br />

version of the software is shown in this output in the future.<br />

Q: 半 衰 期 是 采 用 消 除 相 的 3 个 点 做 的 吗 ?Google Translation: ‘Elimination phase half-life is the use<br />