31.10.2012 Views

Planning safety - Coolit Isoliersysteme Gmbh

Planning safety - Coolit Isoliersysteme Gmbh

Planning safety - Coolit Isoliersysteme Gmbh

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

16<br />

BT-T30 ZBT-T30 BT-T90<br />

Application Utility room Utility room Utility room<br />

Door leaf single-leaf double-leaf single-leaf<br />

Leaf thickness approx. 52 mm approx. 52 mm approx. 73 mm<br />

Leaf surface stainless steel sheet stainless steel sheet stainless steel sheet<br />

Surface variants<br />

Stainless steel sheet circular brush finish, matt brush finish 180 (burnished)<br />

Frames<br />

Version corner frame, wrap-around frame, block frame corner frame, block frame<br />

Frame material and surfaces<br />

Stainless steel sheet circular brush finish, matt brush finish 180 (burnished)<br />

Installation variants*<br />

Masonry (DIN 1053-1) > 115 mm > 115 mm > 175 mm<br />

Concrete (DIN 1045-1) > 100 mm > 100 mm > 140 mm<br />

Aerated concrete (DIN 4165) > 150 mm - - - > 200 mm<br />

Timber frame (DIN 4102-4) F90 > 100 mm F90 > 100 mm F90 > 100 mm<br />

Approved door sizes* Structural opening size Structural opening size Structural opening size<br />

Installed in: masonry, concrete min. 625 mm x 1750 mm<br />

max. 1250 mm x 2500 mm<br />

Installed in: timber frames min. 625 mm x 1750 mm<br />

max. 1250 mm x 2500 mm<br />

Trim variants<br />

min. 1375 mm x 1750 mm<br />

max. 2500 mm x 2500 mm<br />

min. 1375 mm x 1750 mm<br />

max. 2500 mm x 2500 mm<br />

Smoke control door (DIN 18095-1) optional extra optional extra optional extra<br />

Window optional extra optional extra optional extra<br />

Closer optional extra optional extra optional extra<br />

Approval*<br />

Approval granted in: D, CH D, CH D, CH<br />

Safety certificates CE, VDE, TÜV GS, TÜV prototype tested, DIN EN 13241-1, DIN 4102, DIN EN 1634-1<br />

* All measurements for installation variants and approved door sizes are based on German approvals. Country-specific variations are possible.<br />

Approvals depend on the individual installation situation and installation variants.<br />

In European countries not shown in the list, approval may be granted by the local fire protection authorities on application quoting<br />

the German approval number and DIN EN 1634-1 – “cool it” will be glad to help you with any questions. Just ask us.<br />

min. 625 mm x 1750 mm<br />

max. 1250 mm x 2500 mm<br />

min. 625 mm x 1750 mm<br />