ENGINE MAINTENANCE<br />

Please follow these recommendations when you are<br />

changing your fuel filters or strainer elements. Your vehicle's<br />

engine will run better and last longer if you do. See<br />

the engine manufacturer's recommendations for proper<br />

water and micron requirements.<br />

Installing Fuel Filters<br />

When removing filters, cover any electrical equipment and<br />

wiring that might get soaked with fuel. Diesel fuel may permanently<br />

damage electrical insulation.<br />

When installing spin–on (throwaway) filters:<br />

1. Prefill filter with fuel.<br />

2. Moisten gasket with diesel fuel.<br />

3. Hand tighten them only 1/2 to 2/3 turn after gasket<br />

contact. Mechanical tightening of these filters may<br />

distort or crack the filter head.<br />

• When replacing a fuel filter element, do not use a substitute.<br />

Install only filter elements designed for fuel filtration.<br />

First clean and inspect the shell. Then insert<br />

the new element and fill the container at least 2/3 full<br />

of clean fuel before installing the shell<br />

PREVENTIVE MAINTENANCE<br />

NOTE: To expel air from density-type strainer<br />

elements, soak them in clean fuel before installing<br />

them.<br />

• Throw away old gaskets. Replace them with new<br />

ones to ensure a positive seal.<br />

• Position the shell and gasket properly. Then tighten<br />

the cover nut or bolt just enough to prevent fuel leakage.<br />

• After starting the engine, check for leaks around the<br />

filter.<br />

Filter Draining<br />

Check fuel filter/water separator daily. Check with engine<br />

OFF. Depending on the fuel storage facility, more frequent<br />

draining may be required.<br />

1. Open drain valve (by hand only): turn valve screw<br />

counter-clockwise approximately 1 1/2 to 2 turns until<br />

draining occurs. Drain filter sump of water until clear<br />

fuel is visible.<br />

If entrapped water exceeds sump volume, you can either:<br />