Shore Power PART 2: ELECTRIC POWER SYSTEM Circuit Breaker Box Figure -67 Circuit Breaker Box 20 Amp Circuit Breaker Circuit Breaker Box (GFCI) Figure -69 Figure -70 WARNING! Electrical shock hazard. Use of a ground fault circuit interrupter other than that supplied with the Circuit Breaker Box may fail to operate properly and may lead to death, personal injury or equipment damage. Use only the ground fault circuit interrupter that is supplied with the Circuit Breaker Box (Hubbell Part Number GFBF20GYL GFCI). The Circuit Breaker Box houses a 20 Amp circuit breaker and a Ground Fault Circuit Interrupter (GFCI) that provides circuit protection for the 120-Volt AC system. (The Circuit Breaker Box is located in the tool box on the driver’s side of the sleeper.) The circuit breaker is located on the right side of the Circuit Breaker Box. If the breaker is tripped (circuit open) it can be reset by pressing the top of the rocker switch to the ON position. The GFCI is located on the left side of the Circuit Breaker Box. The GFCI will open (disconnecting the power) if a ground fault is detected on the circuit. The unit can be reset by pressing the RESET button on the top of the GFCI. PB00012 Figure -68 – 22 – Y53-6017 R(09/07)
PART 2: ELECTRIC POWER SYSTEM Shore Power Figure -71 i NOTE: Replace GFCI if light on GFCI flashes. If this is not done, outlets will not be powered. Replace with a new Hubbell GFBF20GYL GFCI. 120-Volt AC Outlets Figure -74 i NOTE: The Inverter has its own low-voltage disconnect system that will shut off power to the two duplex outlets when the ComfortClass System Battery voltage gets below 11 Volts. Figure -72 120-Volt AC Outlets PB00013B Figure -73 Two 120-Volt AC duplex style outlets are located in the sleeper compartment, one under the driver’s side lower bunk, the second in the passenger side closet. They are powered by either a shore power electrical supply or by the ComfortClass System Batteries through the Inverter. R(09/07) Y53-6017 – 23 –
- Page 1: Quick Table of Contents Introductio
- Page 4 and 5: Safety Signals PART 1: INTRODUCTION
- Page 6 and 7: The Peterbilt ComfortClass System P
- Page 8 and 9: The Peterbilt ComfortClass System P
- Page 10 and 11: Charging/Jump-Starting Instructions
- Page 12 and 13: Charging/Jump-Starting Instructions
- Page 14 and 15: Charging/Jump-Starting Instructions
- Page 16 and 17: 12-Volt DC System 12-Volt DC System
- Page 18 and 19: 12-Volt DC System PART 2: ELECTRIC
- Page 20 and 21: Shore Power PART 2: ELECTRIC POWER
- Page 22 and 23: Shore Power PART 2: ELECTRIC POWER
- Page 26 and 27: Shore Power PART 2: ELECTRIC POWER
- Page 28 and 29: Controls and Switches PART 3: HEATI
- Page 30 and 31: Using the Heater PART 3: HEATING AN
- Page 32 and 33: Using the Heater Step 3: If you wan
- Page 34 and 35: Using the Air Conditioner PART 3: H
- Page 36 and 37: Using the Air Conditioner PART 3: H
- Page 38 and 39: Cooling System Components PART 3: H
- Page 40 and 41: Cooling System Components PART 3: H
- Page 42 and 43: Preventative Maintenance PART 3: HE
- Page 44: PART 4: TROUBLESHOOTING Concern Pos
Shore Power<br />
PART 2: ELECTRIC POWER SYSTEM<br />
Circuit Breaker Box<br />
Figure -67<br />
Circuit Breaker Box<br />
20 Amp<br />
Circuit Breaker<br />
Circuit Breaker Box<br />
(GFCI)<br />
Figure -69<br />
Figure -70<br />
WARNING! Electrical shock hazard. Use of a<br />
ground fault circuit interrupter other than that<br />
supplied with the Circuit Breaker Box may fail<br />
to operate properly and may lead to death, personal<br />
injury or equipment damage. Use only<br />
the ground fault circuit interrupter that is supplied<br />
with the Circuit Breaker Box (Hubbell Part<br />
Number GFBF20GYL GFCI).<br />
The Circuit Breaker Box houses a 20 Amp circuit breaker<br />
and a Ground Fault Circuit Interrupter (GFCI) that provides<br />
circuit protection for the 120-Volt AC system. (The Circuit<br />
Breaker Box is located in the tool box on the driver’s side<br />
of the sleeper.)<br />
The circuit breaker is located on the right side of the Circuit<br />
Breaker Box. If the breaker is tripped (circuit open) it can<br />
be reset by pressing the top of the rocker switch to the ON<br />
position.<br />
The GFCI is located on the left side of the Circuit Breaker<br />
Box. The GFCI will open (disconnecting the power) if a<br />
ground fault is detected on the circuit. The unit can be<br />
reset by pressing the RESET button on the top of the<br />
GFCI.<br />
PB00012<br />
Figure -68<br />
– 22 – Y53-6017 R(09/07)