31<br />
Controlling IntelliFlo with the IntelliTouch<br />
The IntelliFlo pump can be controlled by an IntelliTouch system via the RS-485 communication cable. In<br />
this configuration IntelliTouch starts and stops the IntelliFlo. IntelliTouch also rewrites many of the<br />
parameters in the IntelliFlo drive's memory, such as the filter cycle start and stop times, pool size and the<br />
clock. The transfer of this data takes several seconds and causes a delay from when the command is given<br />
from the IntelliTouch indoor control panel until the IntelliFlo physically responds. Frequently, these changes<br />
to the IntelliFlo parameters will cause the pump to stop while it recalculates internal parameters and then<br />
restart. This happens automatically but may take 1-2 minutes to complete.<br />
The IntelliFlo LCD control panel is disabled when communicating with the IntelliTouch system and<br />
"DISPLAY NOT ACTIVE" will be displayed. Note that IntelliTouch will not start communicating with the<br />
IntelliFlo until the pump is assigned an IntelliTouch circuit name. For more information, refer to the<br />
IntelliTouch User's Guide (P/N 520102).<br />
Connecting IntelliFlo to IntelliTouch<br />
Connection from IntelliFlo to the IntelliTouch system is via the optional two-wire cable (P/N 350122). The<br />
cable pinout is shown on page 32.<br />
To connect the IntelliFlo cable to the IntelliTouch load center:<br />
1. CAUTION - Switch the main power off to the IntelliTouch load center.<br />
2. Unlatch the IntelliTouch load center front door spring latches, and open the front door.<br />
3. Remove the cover-panel screws securing the high voltage cover-panel, and remove it from the<br />
enclosure.<br />
4. Loosen the two control panel access screws and fold down the outdoor control panel.<br />
5. Insert the two-wire cable into plastic grommet on the bottom of the enclosure and route the wire up<br />
through the low voltage raceway to the Personality board.<br />
Personality Board<br />
Access<br />
screw<br />
Low voltage raceway<br />
Cover-panel<br />
screw<br />
(Cover-panel not<br />
shown)<br />
Plastic grommet<br />
IntelliTouch Load <strong>Center</strong><br />
IntelliFlo <strong>VF</strong> <strong>Installation</strong> and User’s Guide