31<br />

Controlling IntelliFlo with the IntelliTouch<br />

The IntelliFlo pump can be controlled by an IntelliTouch system via the RS-485 communication cable. In<br />

this configuration IntelliTouch starts and stops the IntelliFlo. IntelliTouch also rewrites many of the<br />

parameters in the IntelliFlo drive's memory, such as the filter cycle start and stop times, pool size and the<br />

clock. The transfer of this data takes several seconds and causes a delay from when the command is given<br />

from the IntelliTouch indoor control panel until the IntelliFlo physically responds. Frequently, these changes<br />

to the IntelliFlo parameters will cause the pump to stop while it recalculates internal parameters and then<br />

restart. This happens automatically but may take 1-2 minutes to complete.<br />

The IntelliFlo LCD control panel is disabled when communicating with the IntelliTouch system and<br />

"DISPLAY NOT ACTIVE" will be displayed. Note that IntelliTouch will not start communicating with the<br />

IntelliFlo until the pump is assigned an IntelliTouch circuit name. For more information, refer to the<br />

IntelliTouch User's Guide (P/N 520102).<br />

Connecting IntelliFlo to IntelliTouch<br />

Connection from IntelliFlo to the IntelliTouch system is via the optional two-wire cable (P/N 350122). The<br />

cable pinout is shown on page 32.<br />

To connect the IntelliFlo cable to the IntelliTouch load center:<br />

1. CAUTION - Switch the main power off to the IntelliTouch load center.<br />

2. Unlatch the IntelliTouch load center front door spring latches, and open the front door.<br />

3. Remove the cover-panel screws securing the high voltage cover-panel, and remove it from the<br />

enclosure.<br />

4. Loosen the two control panel access screws and fold down the outdoor control panel.<br />

5. Insert the two-wire cable into plastic grommet on the bottom of the enclosure and route the wire up<br />

through the low voltage raceway to the Personality board.<br />

Personality Board<br />

Access<br />

screw<br />

Low voltage raceway<br />

Cover-panel<br />

screw<br />

(Cover-panel not<br />

shown)<br />

Plastic grommet<br />

IntelliTouch Load <strong>Center</strong><br />

IntelliFlo <strong>VF</strong> <strong>Installation</strong> and User’s Guide