23<br />

Features Mode<br />

The Feature mode can be used with water features such as spa, cleaner, waterfalls, etc. You can schedule<br />

start and stop times for each feature. All Features are operated using Flow control. The Feature mode and<br />

Filter mode are run simultaneously. The three types of features are; Features 1 & 2, Features 3 -9 and<br />

M.O. Flo:<br />

Features 1 and 2<br />

Feature 1 and Feature 2 run for a pre-defined duration with a specifically set flow. If Feature 1 or Feature 2<br />

buttons are pressed, all other Features are temporarily deactivated. Feature 1 or Feature 2 cannot be used<br />

in Backwash Mode. Features 1 and 2 have a higher priority than the pre-programmed Features 3-9. After<br />

the preset duration time for the Feature 1(2), IntelliFlo will switch back to the “Filter” mode if the IntelliFlo<br />

was in “Filter” mode when the Feature 1 (2) button had been pressed. After the preset duration time for the<br />

Feature 1(2), the IntelliFlo will switch back to the “<strong>Manual</strong>” mode if IntelliFlo was in “<strong>Manual</strong>” mode when<br />

the Feature 1 (2) button had been pressed.<br />

Features 3 -9<br />

Features 3 through 9 are only active in Filter mode. These features run a set flow for a specified time. The<br />

Features 3-9 can not overlap.<br />

M. O. Flo<br />

The M. O. Flo feature automatically increases the pump flow to allow the system heater to check the water<br />

temperature and switch on if necessary. This feature is only active when the pump is running a filter cycle.<br />

Once the heater checks for heat and discovers it must fire it will send a signal back to IntelliFlo to go into<br />

“Heater” mode. M.O. Flo only works during the “Filter” mode selected time cycles<br />

IntelliFlo <strong>VF</strong> <strong>Installation</strong> and User’s Guide