19<br />

Filter Mode (Continued)<br />

Clean Filter Pressure Example<br />

The following example shows the “Clean Filter Pressure” set to 14 PSI.<br />

IntelliFlo ®<br />

FILTER 1:37<br />

43.GPM<br />

FLOW<br />

RUNNING Schedule<br />

10<br />

psi<br />

IntelliFlo ®<br />

Alert<br />

Service System Soon<br />

24<br />

psi<br />

Filter<br />

Vacuum<br />

Back<br />

Wash<br />

<strong>Manual</strong><br />

Filter<br />

Filter<br />

Vacuum<br />

Back<br />

Wash<br />

<strong>Manual</strong><br />

Filter<br />

Select<br />

Escape<br />

Select<br />

Escape<br />

On<br />

Enter<br />

Menu<br />

On<br />

Enter<br />

Menu<br />

Warn.<br />

Warn.<br />

Alarm<br />

Alarm<br />

Feature<br />

1<br />

Feature<br />

2<br />

Start<br />

Stop<br />

Reset<br />

Feature<br />

1<br />

Feature<br />

2<br />

Start<br />

Stop<br />

Reset<br />

Pump newly installed and<br />

system run for the first<br />

time<br />

12 months later filter attains<br />

24 psi of internal pressure<br />

which is a 14 psi increase<br />

Alert Status<br />

Once the “Alert” is triggered the yellow warning LED is lit and “Alert” is displayed on<br />

the screen. The pump will reduce speed to maintain 14 PSI of head pressure and stop<br />

managing flow. Note the following:<br />

• The % clean filter pressure has reached 100%.<br />

IntelliFlo ®<br />

Alert<br />

Service System Soon<br />

• If parameter is set to 14 PSI every 10% on the display is 1.4 psi on the filter.<br />

Filter<br />

Vacuum<br />

Back<br />

Wash<br />

<strong>Manual</strong><br />

• If the parameter is set to 10 PSI every 10% on the display is 1 psi on the filter.<br />

Select<br />

Escape<br />

• The filter must be cleaned or backwashed to reduce the pressure. Even if the<br />

system has a cartridge filter the IntelliFlo must be started in Backwash Mode<br />

with a clean filter to reset the fault and "zero" the IntelliFlo's filter status reading.<br />

On<br />

Warn.<br />

Alarm<br />

Feature<br />

1<br />

Feature<br />

2<br />

Enter<br />

Start<br />

Stop<br />

Menu<br />

Reset<br />

Note: For a complete list of IntelliFlo alert warnings, refer to “Alert and<br />

Warning” on page 49.<br />

IntelliFlo <strong>VF</strong> <strong>Installation</strong> and User’s Guide

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!