Filter Mode (Continued)<br />

Filter Cycle Settings<br />

Note: The control panel is disabled when the <strong>Intelliflo</strong> is communicating with an IntelliTouch.<br />

"DISPLAY NOT ACTIVE!" will be displayed.<br />

NAME<br />

Turnovers<br />

Day<br />

Per<br />

Cycles per<br />

Day<br />

Clean Filter<br />

Pressure<br />

Start Cycle 1<br />

Stop Cycle 1<br />

Start Cycle 2<br />

Stop Cycle 2<br />

Start Cycle 3<br />

Stop Cycle 3<br />

Start Cycle 4<br />

Stop Cycle 4<br />

VALUE<br />

1-8 (Default 1)<br />

1-4 Cycles (Default 1)<br />

1-50 PSI (Default 14<br />

PSI)<br />

1:00 -12:59 HH.MM<br />

am/pm (Default 9:00<br />

am)<br />

1:00 -12:59 HH.MM<br />

am/pm (Default 9:00<br />

pm)<br />

1:00 -12:59 HH.MM<br />

am/pm (Default 9:10<br />

pm)<br />

1:00 -12:59 HH.MM<br />

am/pm (Default 9:20<br />

pm)<br />

1:00 -12:59 HH.MM<br />

am/pm (Default 9:30<br />

pm)<br />

1:00 -12:59 HH.MM<br />

am/pm (Default 9:40<br />

pm)<br />

1:00 -12:59 HH.MM<br />

am/pm (Default 9:50<br />

pm)<br />

1:00 -12:59 HH.MM<br />

am/pm (Default 10:00<br />

pm)<br />

DESCRIPTION<br />

The number of times per day the volume of water setup<br />

in "<strong>Pool</strong> Volume" will be moved.<br />

The number of cycles (start and stop) the IntelliFlo must<br />

do per day.<br />

The differential pressure from the 0-pressure to 100%<br />

filter status.<br />

Start<br />

time for cycle 1 (if start and stop is the same time<br />

the IntelliFlo will run 24*7).<br />

Stop<br />

time for cycle 1 (if start and stop is the same time<br />

the IntelliFlo will run 24*7).<br />

S tart time for cycle 2. If "Cycles per day" is below 2,<br />

"OFF" will be shown in the display and data cannot be<br />

entered.<br />

S top time for cycle 2. If "Cycles per day" is below 2,<br />

"OFF" will be shown in the display and data cannot be<br />

entered.<br />

S tart time for cycle 3. If "Cycles per day" is below 3,<br />

"OFF" will be shown in the display and data cannot be<br />

entered.<br />

S top time for cycle 3. If "Cycles per day" is below 3,<br />

"OFF" will be shown in the display and data cannot be<br />

entered.<br />

S tart time for cycle 4. If "Cycles per day" is below 4,<br />

"OFF" will be shown in the display and data cannot be<br />

entered.<br />

S top time for cycle 4. If "Cycles per day" is below 4,<br />

"OFF" will be shown in the display and data cannot be<br />

entered.<br />

Based on “<strong>Pool</strong> Volume”, “Turnovers per day” and the total number of hours for Cycle 1 + 2 + 3 + 4<br />

the flow must be calculated:<br />

" <strong>Pool</strong>Volume"<br />

× " Turnovers pr day"<br />

Flow =<br />

Cycle1+<br />

Cycle 2 + Cycle3+<br />

Cycle 4<br />

Note: Only enabled cycles are included in the calculation<br />