This section describes how to use the IntelliFlo pump control panel.<br />
Metering the System<br />
Section 3<br />
Operating IntelliFlo<br />
The first step to operating and programming IntelliFlo is to know what is being used in the<br />
pool system. After the devices are selected you can then set valves for the appropriate<br />
features and use the “<strong>Manual</strong>” mode to measure flow rates for the types or series of<br />
devices that require flow. When an appropriate flow rate or rates are found for a device<br />
or series of devices, you should note that flow rate for programming later.<br />
Note: If the pool system uses a filter, always monitor pressure at the filter when<br />
changing the speed (RPM) or flow (GPM) from IntelliFlo.<br />
<strong>Manual</strong> Mode<br />
Operating IntelliFlo in manual mode is typically used for service and testing purposes only.<br />
To operate IntelliFlo in manual mode:<br />
1. Ensure that the green power LED is on.<br />
2. Press the <strong>Manual</strong> button.<br />
3. Use the Up and Down arrow buttons to view the current power, actual speed and flow:<br />
• Power Menu (Watts): Displays current power to the motor shaft in continuous watts<br />
• Actual Speed (RPM): Displays RPM speed when flow and RPM control is used<br />
• Actual Flow (GPM): Displays actual flow when using flow control<br />
• Set Speed (RPM): Set IntelliFlo to run at a continuous speed<br />
• Set Flow (GPM): Set IntelliFlo in flow control to allow the pump to change speed to manage the<br />
flow rate based on system changes<br />
9<br />
IntelliFlo ®<br />
MANUAL 12:15<br />
15.W<br />
POWER<br />
STOPPED<br />
IntelliFlo ®<br />
MANUAL 12:15<br />
10.RPM<br />
ACTUAL SPEED<br />
STOPPED<br />
IntelliFlo ®<br />
MANUAL 12:15<br />
13.GPM<br />
FLOW<br />
STOPPED<br />
IntelliFlo ®<br />
MANUAL 12:15<br />
10.RPM<br />
Set SPEED<br />
STOPPED<br />
IntelliFlo ®<br />
MANUAL 12:15<br />
580.GPM<br />
Set FLOW<br />
STOPPED<br />
Filter<br />
Vacuum<br />
Back<br />
Wash<br />
<strong>Manual</strong><br />
Filter<br />
Vacuum<br />
Back<br />
Wash<br />
<strong>Manual</strong><br />
Filter<br />
Vacuum<br />
Back<br />
Wash<br />
<strong>Manual</strong><br />
Filter<br />
Vacuum<br />
Back<br />
Wash<br />
<strong>Manual</strong><br />
Filter<br />
Vacuum<br />
Back<br />
Wash<br />
<strong>Manual</strong><br />
Select<br />
Escape<br />
Select<br />
Escape<br />
Select<br />
Escape<br />
Select<br />
Escape<br />
Select<br />
Escape<br />
On<br />
Enter<br />
Menu<br />
On<br />
Enter<br />
Menu<br />
On<br />
Enter<br />
Menu<br />
On<br />
Enter<br />
Menu<br />
On<br />
Enter<br />
Menu<br />
Warn.<br />
Warn.<br />
Warn.<br />
Warn.<br />
Warn.<br />
Alarm<br />
Alarm<br />
Alarm<br />
Alarm<br />
Alarm<br />
Feature<br />
1<br />
Feature<br />
2<br />
Start<br />
Stop<br />
Reset<br />
Feature<br />
1<br />
Feature<br />
2<br />
Start<br />
Stop<br />
Reset<br />
Feature<br />
1<br />
Feature<br />
2<br />
Start<br />
Stop<br />
Reset<br />
Feature<br />
1<br />
Feature<br />
2<br />
Start<br />
Stop<br />
Reset<br />
Feature<br />
1<br />
Feature<br />
2<br />
Start<br />
Stop<br />
Reset<br />
<strong>Manual</strong><br />
Note: No sensors except the flow control will work while in “<strong>Manual</strong>” mode. Suction Blockage will<br />
not work in this mode.<br />
IntelliFlo <strong>VF</strong> <strong>Installation</strong> and User’s Guide