Tangential method for circular ducts<br />

In the "tangential method" applicable to circular ducts, the sampling plane is divided into equal areas. The sampling points, one at<br />

the centre of each area, are located on two or more diameters (sampling lines), there being no sampling point at the centre of the<br />

duct (see Figure C.2).<br />

Figure C.2 — Sampling point positions in circular ducts - Tangential method<br />

(showing positions for ducts over 2 m diameter)<br />

The locations of the sampling points on each diameter are dependent on the number of sampling points on each diameter but<br />

are independent of the number of sampling diameters.<br />

For circular ducts where two sampling lines (diameters) are sufficient, the distance can calculate by the formula in our<br />