10. Determination of flow direction with Pitot tubes<br />

Type Prandtl-Pitot tube<br />

The type Prandtl Pitot tube provides an accurate measure of gas velocity when the Pitot tube is aligned (yawed) within<br />

15° of the direction of the gas flow. However, the pressure difference between the two pressure-sensing orifices decreases<br />

sharply when misalignment exceeds 15°, until a negative response occurs when the head is at 90° to the gas flow. This<br />

provides a simple method for estimating gas flow direction and may be used to test for the presence of swirling flow within<br />

the duct.<br />

Type S Pitot tube<br />

The type S Pitot tube accurately measures the gas velocity to within 4 % when the Pitot tube is aligned (yawed) within 15°<br />

of the direction of the gas flow. However, when the planes of the Pitot tube pressure-sensing orifices are parallel to the stack<br />

flow, a null (zero) reading is obtained. Thus, the direction of swirling flow can be determined by rotating the type S Pitot tube<br />

(with the manometer properly zeroed and levelled) until a null reading is obtained. The direction of flow shall be parallel to<br />

the pressure-sensing orifice planes.<br />