Isokinetic rate<br />

If the mean actual isokinetic rate during the sampling at the sampling plane differs for more than –5 % to +15 %, the<br />

measurement is not valid.<br />

If this criterion is not fulfilled due to frequent variation of the flow rate in the duct, see 10.2. 10.5<br />

Deposits of dust on non-weighed parts upstream the filter<br />

Experimental work carried out when preparing this Standard proved that dust deposits upstream of the<br />

filter are often in the range of 10 % to 30 % of the total dust when sampling gases from waste incinerators at<br />

concentration around 5 mg/m 3 .<br />

These deposits depend probably on the design of the sampling equipment, and on the kind of dust to be sampled, but no<br />

efficient means was found to keep them at a negligible level. For this reason all non weighed parts of the sampling<br />

equipment prior to the filter shall be rinsed. The mass of dust on non-weighed parts upstream of the filter shall be<br />

indicated in the test report, besides the mass on the filters used during the same measurement series.<br />

When sampling with in-stack filtration devices with no bends between the nozzle and filter holder on non saturated gases, with<br />

a temperature well above the stack gas dew point, the upstream deposits do not have to be quantified provided that<br />

validation has been carried out at similar conditions as the process to prove that the deposits, expressed in the same<br />

units as the measurement results (e.g. in milligrams per cubic metre) do not exceed 10 % of the daily average limit value<br />

set for the process.<br />

Calculation<br />

See our formula sheet or ask for our excel file.<br />