280<br />

QiiiS T J^N_J_2 . (Continued)<br />

- 5<br />

Finally, I disagree with the Commission's stated conclusion that<br />

because the Davis-Besse and Rancho Seco events had little or no<br />

offsite consequences, they did not pose an undue risk to the<br />

public health and safety. In my view, both events disclosed<br />

examples of past management practices which resulted in a<br />

significant deterioration in equipment condition and reliability,<br />

and in poor operations performance. These management breakdowns<br />

have resulted in extended plant shutdowns at both plants and in<br />

extensive improvement programs which are aimed at correcting the<br />

many consequences of the management failures at these plants. In<br />

my view, the management breakdowns at these plants and the<br />

resulting deterioration in plant safety systems reliability and<br />

operations performance posed an undue risk to the public health<br />

and safety by creating the potential for a much more serious<br />

accident.