Solutions for the Wrist - Stryker
Solutions for the Wrist - Stryker Solutions for the Wrist - Stryker
Solutions for the Wrist Variax, Matrix, TwinFix, SPS, Asnis III, Hoffmann® II Compact, HydroSet, KnifeLight, CORE Micro System
- Page 2 and 3: Introduction The Distal Radius and
- Page 4 and 5: Plating Systems Matrix SmartLock Po
- Page 6 and 7: External Fixation and HA Bone Subst
- Page 8: Trauma, Extremities & Deformities B
<strong>Solutions</strong> <strong>for</strong> <strong>the</strong> <strong>Wrist</strong><br />
Variax, Matrix, TwinFix, SPS,<br />
Asnis III, Hoffmann® II<br />
Compact, HydroSet,<br />
KnifeLight, CORE Micro System
Introduction<br />
The Distal Radius<br />
and Carpals<br />
Fractures of <strong>the</strong> Distal Radius and<br />
Carpals account <strong>for</strong> over 20% of all<br />
fractures annually. These fractures also<br />
afflict <strong>the</strong> young and old alike.<br />
Additonally, surgeons are treating a<br />
large number of repetitive stress<br />
disorders. For this reason, today’s<br />
surgeons need many treatment options<br />
in order to effectively rehabilitate <strong>the</strong>ir<br />
patients.<br />
<strong>Stryker</strong>® realizes this need, and<br />
through continued innovation, offers a<br />
full line of implants and instruments<br />
dedicated to <strong>the</strong> treatment fractures<br />
and disorders of <strong>the</strong> wrist.<br />
2
Plating Systems<br />
VariAx Polyaxial<br />
Locking Plate<br />
System<br />
The VariAx Distal Radius Plating<br />
System represents <strong>the</strong> next generation<br />
of bone fixation <strong>for</strong> virtually all of<br />
your Distal Radius fracture needs. It is<br />
designed to offer a comprehensive<br />
selection of plates, screws, pegs and<br />
unique instrumentation necessary to<br />
maintain <strong>the</strong> stability of <strong>the</strong> distal<br />
radius lesion, while providing your<br />
surgical staff a user-friendly module<br />
layout.<br />
Left<br />
Anatomical<br />
Volar Plates<br />
Right<br />
Universal<br />
Volar Plates<br />
Dorsal<br />
Plates<br />
Radial<br />
Column<br />
Plates Ulnar<br />
Column<br />
Plates<br />
Plates<br />
All plates are made of pure titanium,<br />
and <strong>the</strong>y are treated with Type 2<br />
Annodisation to limit tissue adherence.<br />
Each hole is capable of 15° locking<br />
screw trajectory in any direction. The<br />
2mm profile height of <strong>the</strong> plate<br />
provides added strength to <strong>the</strong><br />
plate/screw construct.<br />
Screws<br />
2.0mm<br />
Smooth<br />
Locking<br />
2.3mm<br />
Locking<br />
2.7mm<br />
Locking<br />
2.7mm<br />
Partial Thread<br />
Locking<br />
2.3mm<br />
Non-<br />
Locking<br />
2.7mm 2.7mm<br />
Non- Partial Thread<br />
Locking Non-Locking<br />
All screws are made of a titanium alloy,<br />
and are offered in both 2.3mm and<br />
2.7mm diameters in locked and nonlocked<br />
designs. 2.0mm Locking Pegs<br />
are also offered in <strong>the</strong> system.<br />
3
Plating Systems<br />
Matrix SmartLock<br />
Polyaxial Locking<br />
Plate System<br />
The Matrix SmartLock System<br />
combines polyaxial locking with a lowprofile<br />
plate design. With a 1.5mm<br />
profile height, <strong>the</strong>se pure titanium<br />
plates provide a locking screw<br />
trajectory of 10° in any direction.<br />
Screw Options<br />
Simple instrumentation and product<br />
offering is <strong>the</strong> key to this system.<br />
Hospital inventory costs can be<br />
minimised. The system carries 2.7mm<br />
screws in locking and non-locking<br />
versions, as well as a 3.0mm cancellous<br />
screws.<br />
Plate profile<br />
height 1.5 mm<br />
2.7 mm 2.7 mm 3.0 mm<br />
Locking Screw Bone Screw Cancellous Bone Screw<br />
SPS Conventional<br />
Plating System<br />
When faced with more simple fracture<br />
patterns and good quality bone,<br />
locking plates could be a costly and<br />
unnecessary treatment option.<br />
<strong>Stryker</strong>®’s SPS Conventional Small<br />
Fragment Plating System offers T-<br />
Plates and Oblique T-Plates <strong>for</strong> use in<br />
<strong>the</strong> Distal Radius. Titanium and<br />
Stainless Steel versions are available.<br />
4
Cannulated Screw Systems<br />
Asnis III<br />
Cannulated<br />
Screw System<br />
Cannulated screws are one <strong>the</strong> most<br />
used treatment options in orthopedics<br />
today. From <strong>the</strong> Foot to <strong>the</strong> Pelvis to<br />
<strong>the</strong> Forearm, cannulated screws are<br />
indispensable in treating a variety of<br />
fractures. In <strong>the</strong> Distal Radius region,<br />
a 4mm screw may be used to lag a<br />
fractured Radial Styloid. Using<br />
standard compression techniques, <strong>the</strong><br />
fracture can be reduced and<br />
maintained with minimal internal<br />
fixation.<br />
TwinFix 3.2mm<br />
Cannulated<br />
Compression<br />
Screw<br />
The most commonly fractured carpal<br />
bone is <strong>the</strong> Scaphoid. <strong>Stryker</strong>® offers a<br />
unique solution <strong>for</strong> this fracture in <strong>the</strong><br />
TwinFix. This device is designed with<br />
two independent screw threads which<br />
provide controlled compression to <strong>the</strong><br />
fracture site. With simple<br />
instrumentation and a variety of<br />
lengths, <strong>the</strong> TwinFix offers a smart<br />
solution <strong>for</strong> treating scaphoid<br />
fractures.<br />
5
External Fixation and HA Bone Substitute<br />
Hoffmann ® II<br />
Compact<br />
If <strong>the</strong> soft tissues or fracture pattern<br />
calls <strong>for</strong> an External Fixator, <strong>the</strong><br />
Hoffmann® II Compact could be <strong>the</strong><br />
treatment of choice. With <strong>the</strong> patented<br />
Snap Fit couplings and <strong>the</strong> Apex® self<br />
drilling half pins, this system is one of<br />
<strong>the</strong> leading External Fixation systems<br />
in <strong>the</strong> market today. And with <strong>the</strong><br />
MRI version of <strong>the</strong> Hoffmann® II<br />
Compact, this fixator can be used<br />
safely in an MRI environment up to<br />
3.0 Tesla.<br />
HydroSet<br />
Injectable HA<br />
Bone Substitute<br />
Fracture gaps are often seen in<br />
comminuted Distal Radius fractures.<br />
Some surgeons prefer to use bone<br />
substitutes to fill <strong>the</strong>se gaps. <strong>Stryker</strong>®<br />
offers an innovative HA Bone<br />
Substitute with HydroSet .<br />
The injectable self-setting calcium<br />
phosphate material allows <strong>the</strong> surgeon<br />
to fill bone voids or gaps of <strong>the</strong> skeletal<br />
system (i.e., extremities, craniofacial,<br />
spine, and pelvis). These defects may<br />
be surgically created or osseous defects<br />
created from traumatic injury to <strong>the</strong><br />
bone.<br />
HydroSet is delivered in 3, 5, 10, or<br />
15cc quantities. 3cc and 5cc are<br />
normally suitable <strong>for</strong> voids in <strong>the</strong><br />
Distal Radius.<br />
6
Instrumentation<br />
KnifeLight -<br />
Instrument <strong>for</strong><br />
Minimal Invasive<br />
Carpal Tunnel<br />
Ligament Release<br />
Carpal Tunnel Syndrome is a common<br />
repetitive stress disorder which affects<br />
up to 10% of <strong>the</strong> population today.<br />
<strong>Stryker</strong>® offers a product which treats<br />
this painful disorder in a minimally<br />
invasive surgical approach.<br />
The KnifeLight combines a surgical<br />
blade with a light in its handle which<br />
allows visualization of soft tissues.<br />
CORE Micro<br />
System<br />
Small bone surgery requires special<br />
solutions. There<strong>for</strong>e <strong>the</strong> CORE system<br />
is an ideal solution. The electrical<br />
system consists of manifold<br />
components which can be configured<br />
individually.<br />
+ Powerful drilling, cutting and<br />
burring<br />
+ Versatile applications<br />
+ Simple operation of <strong>the</strong> console<br />
and components<br />
7
Trauma, Extremities & De<strong>for</strong>mities<br />
Biologics<br />
Surgical Products<br />
Neuro & ENT<br />
<strong>Stryker</strong> Trauma AG<br />
Bohnackerweg 1<br />
CH-2545 Selzach<br />
Switzerland<br />
www.osteosyn<strong>the</strong>sis.stryker.com<br />
The in<strong>for</strong>mation presented in this brochure is intended to demonstrate a <strong>Stryker</strong> product. Always refer to <strong>the</strong> package<br />
insert, product label and/or user instructions be<strong>for</strong>e using any <strong>Stryker</strong> product. Surgeons must always rely on <strong>the</strong>ir own<br />
clinical judgment when deciding which products and techniques to use with <strong>the</strong>ir patients. Products may not be available<br />
in all markets. Product availability is subject to <strong>the</strong> regulatory or medical practices that govern individual markets. Please<br />
contact your <strong>Stryker</strong> representative if you have questions about <strong>the</strong> availability of <strong>Stryker</strong> products in your area.<br />
<strong>Stryker</strong> Corporation or its subsidiary owns <strong>the</strong> registered trademark: <strong>Stryker</strong><br />
<strong>Stryker</strong> Corporation or its subsidiary owns, uses or has applied <strong>for</strong> <strong>the</strong> following trademarks: Asnis, VariAx, Hoffmann,<br />
Compact, Apex, HydroSet<br />
Literature Number: 982326<br />
LOT A4206<br />
Copyright © 2006 <strong>Stryker</strong><br />
Printed in Switzerland