Ordering Information – Implants 8mm Tibial Nail, Standard REF Diameter Length mm mm 1822-0824S 8.0 240 1822-0825S 8.0 255 1822-0827S 8.0 270 1822-0828S 8.0 285 1822-0830S 8.0 300 1822-0831S 8.0 315 1822-0833S 8.0 330 1822-0834S 8.0 345 1822-0836S 8.0 360 1822-0837S 8.0 375 1822-0839S 8.0 390 1822-0840S 8.0 405 1822-0842S 8.0 420 8mm Tibial Nail, Proximal REF Diameter Length mm mm 1823-0824S 8.0 240 1823-0825S 8.0 255 1823-0827S 8.0 270 1823-0828S 8.0 285 1823-0830S 8.0 300 1823-0831S 8.0 315 1823-0833S 8.0 330 1823-0834S 8.0 345 1823-0836S 8.0 360 1823-0837S 8.0 375 1823-0839S 8.0 390 1823-0840S 8.0 405 1823-0842S 8.0 420 End Caps Fully Standard Threaded +10mm +15mm +5mm +20mm REF Diameter Length mm mm 1827-0004S 7.0 Fully Threaded 1822-0003S 8.0 Standard 1822-0005S 11.5 + 5mm 1822-0010S 11.5 +10mm 1822-0015S 11.5 +15mm 1822-0020S 11.5 +20mm 1822-0025S 11.5 +25mm 1822-0030S 11.5 +30mm 1822-0035S 11.5 +35mm Advanced Compression Screws, Tibia REF Diameter mm 1822-0001S 8.0 +25mm +30mm +35mm End Caps (optional) REF Diameter Length mm mm 1823-0005S 8.0 + 5mm 1823-0010S 8.0 + 10mm 1823-0015S 8.0 + 15mm Implants in sterile packaging Note: Check with local representative regarding availability of nail sizes and types. Partially Threaded Locking Screws (Shaft Screws) are used in conjunction with the Advanced Compression Screw feature of the Distal and Standard Nails, or may also be used as a “Blocking Screw“ with all three nail types, including the Proximal Nail. (See optional “Blocking Screw Technique“ section on pages 27 and 28) 32

Ordering Information – Instruments REF Description REF Description Quantity T2 Basic Long 702429 Teardrop Handle, AO Coupling 703165 Protection Sleeve, Retrograde 1806-0022 Guide Wire Ruler T2 Tibia 1806-0010 X-Ray Ruler, Tibia 1806-0050 K-Wire 3×285mm 2 1806-0370 Nail Holding Screw 2 1806-1001 Targeting Arm 1806-1002 Nail Adapter 1806-0032 Awl Plug 1806-0041 Awl 1806-0110 Universal Rod 1806-0125 Reduction Spoon 1806-4260* Drill Ø4.2×340mm, AO 2 1806-4280* Drill Ø4.2×130mm, AO 2 1806-5000* Drill Ø5.0×230mm, AO 2 1806-9910 T2 Tibia Instrument Tray 1806-0130 Wrench 8mm/10mm 1806-0135 Insertion Wrench, 10mm 1806-0150 Strike Plate 1806-0170 Slotted Hammer 1806-0185 Tissue Protection Sleeve, Long 1806-0203 Screwdriver, Self-Holding, Extra Short (3.5) 1806-0215 Drill Sleeve, Long 1806-0227 Screwdriver Shaft AO, Long 1806-0233 Screwdriver, Self-Holding, Long (3.5) 1806-0268 Screwdriver Shaft, Compression (Hex 3.5) 1806-0271 Guide Wire Pusher 1806-0315 Trocar, Long REF Description T2 8mm Tibial Nail Instruments 1806-0073S Teflon Tube 1806-0090 Guide Wire, Smooth Tip 3×800mm (outside of U. S.) 1806-0090S Guide Wire, Smooth Tip 3×800mm, sterile (U. S.) 1806-3550 Drill Ø3.5×130mm AO (outside of U. S.) 1806-3550S Drill Ø3.5×130mm AO, sterile (U. S.) 1806-3555 Drill Ø3.5×130mm Tri-flat (outside of U. S.) 1806-3555S Drill Ø3.5×130mm Tri-flat, sterile (outside of U. S.) 1806-0325 Screw Gauge, Long 1806-0331 Screw Gauge (20-120mm) 1806-0350 Extraction Rod, Conical (Ø8mm) 1806-0365 Screw Scale, Long 1806-1095 Guide Wire Handle 1806-1096 Guide Wire Handle Chuck 1806-2014 Rigid Reamer Ø12mm 1806-9900 T2 Basic Long Instrument Tray Caution: 8mm Nails require 4mm Fully Threaded Screws for locking at the non-driving end. * Instruments designated “Outside of the U. S.” may not be ordered for the U. S. market. 33

Ordering Information – Implants<br />

8mm <strong>Tibial</strong> Nail, Standard<br />

REF Diameter Length<br />

mm<br />

mm<br />

1822-0824S 8.0 240<br />

1822-0825S 8.0 255<br />

1822-0827S 8.0 270<br />

1822-0828S 8.0 285<br />

1822-0830S 8.0 300<br />

1822-0831S 8.0 315<br />

1822-0833S 8.0 330<br />

1822-0834S 8.0 345<br />

1822-0836S 8.0 360<br />

1822-0837S 8.0 375<br />

1822-0839S 8.0 390<br />

1822-0840S 8.0 405<br />

1822-0842S 8.0 420<br />

8mm <strong>Tibial</strong> Nail, Proximal<br />

REF Diameter Length<br />

mm<br />

mm<br />

1823-0824S 8.0 240<br />

1823-0825S 8.0 255<br />

1823-0827S 8.0 270<br />

1823-0828S 8.0 285<br />

1823-0830S 8.0 300<br />

1823-0831S 8.0 315<br />

1823-0833S 8.0 330<br />

1823-0834S 8.0 345<br />

1823-0836S 8.0 360<br />

1823-0837S 8.0 375<br />

1823-0839S 8.0 390<br />

1823-0840S 8.0 405<br />

1823-0842S 8.0 420<br />

End Caps<br />

Fully Standard<br />

Threaded<br />

+10mm<br />

+15mm<br />

+5mm<br />

+20mm<br />

REF Diameter Length<br />

mm<br />

mm<br />

1827-0004S 7.0 Fully Threaded<br />

1822-0003S 8.0 Standard<br />

1822-0005S 11.5 + 5mm<br />

1822-0010S 11.5 +10mm<br />

1822-0015S 11.5 +15mm<br />

1822-0020S 11.5 +20mm<br />

1822-0025S 11.5 +25mm<br />

1822-0030S 11.5 +30mm<br />

1822-0035S 11.5 +35mm<br />

Advanced Compression Screws, Tibia<br />

REF<br />

Diameter<br />

mm<br />

1822-0001S 8.0<br />

+25mm +30mm +35mm<br />

End Caps (optional)<br />

REF Diameter Length<br />

mm<br />

mm<br />

1823-0005S 8.0 + 5mm<br />

1823-0010S 8.0 + 10mm<br />

1823-0015S 8.0 + 15mm<br />

Implants in sterile packaging<br />

Note:<br />

Check with local representative<br />

regarding availability of nail sizes<br />

and types.<br />

Partially Threaded Locking Screws (Shaft Screws) are<br />

used in conjunction with the Advanced Compression<br />

Screw feature of the Distal and Standard Nails, or may<br />

also be used as a “Blocking Screw“ with all three nail<br />

types, including the Proximal Nail.<br />

(See optional “Blocking Screw <strong>Technique</strong>“ section<br />

on pages 27 and 28)<br />