10.05.2014 Views

VariAx Foot Flyer - Stryker

VariAx Foot Flyer - Stryker

VariAx Foot Flyer - Stryker

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Plate Options<br />

T-Plate<br />

Broad Straight<br />

Plate<br />

Curved<br />

Plate<br />

Trauma, Extremities & Deformities<br />

L-Plate<br />

Biologics<br />

Trauma, Extremities & Deformities<br />

Biologics<br />

<strong>VariAx</strong> <strong>Foot</strong><br />

Locking Plate System<br />

Rectangular<br />

Plate<br />

Oblique<br />

Surgical T-Plate Products<br />

Neuro & ENT<br />

Surgical Products<br />

Neuro & ENT<br />

• Comprehensive Locking<br />

and Non-Locking System<br />

• Polyaxial Locking<br />

• Low Profile Plate Design<br />

H-Plate<br />

3-D Plate<br />

Calcaneus Standard Plate<br />

Calcaneus Mesh Plate<br />

Screw Options<br />

2.7mm<br />

Locking<br />

2.7mm<br />

Non-<br />

Locking<br />

3.5mm<br />

Locking<br />

3.5mm<br />

Non-<br />

Locking<br />

<strong>Stryker</strong> Leibinger GmbH & Co. KG<br />

Bötzinger Strasse 39-41<br />

D-79111 Freiburg - Germany<br />

www.osteosynthesis.stryker.com<br />

The information presented in this brochure is intended to demonstrate a <strong>Stryker</strong> product. Always<br />

refer to the package insert, product label and/or user instructions before using any <strong>Stryker</strong> product.<br />

Surgeons must always rely on their own clinical judgment when deciding which products and<br />

techniques to use with their patients. Products may not be available in all markets. Product availability<br />

is subject to the regulatory or medical practices that govern individual markets. Please contact your<br />

<strong>Stryker</strong> representative if you have questions about the availability of <strong>Stryker</strong> products in your area.<br />

<strong>Stryker</strong> Corporation or its subsidiary owns the registered trademark: <strong>Stryker</strong><br />

<strong>Stryker</strong> Corporation or its subsidiary owns, uses or has applied for the following trademarks:<br />

<strong>VariAx</strong>, Asnis, AxSOS, Hydroset<br />

Literature Number: 90-07807<br />

LOT A4807<br />

Copyright © 2007 <strong>Stryker</strong>


Introduction<br />

Just as no two feet are alike, no two foot surgeries have the<br />

same fixation needs. Designing a better foot plating system<br />

means creating a plate that can adjust to these differences.<br />

The comprehensive <strong>VariAx</strong> <strong>Foot</strong> Locking Plating System uses<br />

SmartLock technology to expand your surgical options.<br />

This patented mechanism allows polyaxial locking, and nonlocking<br />

screw placement, all in the same screw hole.<br />

With more options for screw placement, you now have more<br />

choices on how to best treat each patient. Also, the low profile<br />

design of each plate helps to minimize soft tissue irritation.<br />

Locking Options<br />

• Polyaxial Locking<br />

SmartLock technology goes<br />

one step further. <strong>VariAx</strong> <strong>Foot</strong><br />

Locking Plates permit polyaxial<br />

screw placement. Locking<br />

screws can be angled up to up<br />

to ±15° in any direction for a<br />

total range of 30°. Simply place<br />

the Polyaxial Drill Guide in<br />

the screw hole to select the<br />

appropriate angle. Each plate<br />

can accommodate a variety of<br />

locking or non-locking screws<br />

at various angles to allow you<br />

to easily adjust to the particular<br />

needs of each patient.<br />

Complementary Products<br />

Asnis Micro Cannulated Screws<br />

HydroSet HA Injectable<br />

Bone Substitute<br />

T2 Ankle Arthrodesis Nail<br />

Locking Options<br />

• Comprehensive Locking<br />

and Non-Locking System<br />

<strong>VariAx</strong> <strong>Foot</strong> Locking Plates<br />

incorporate the SmartLock<br />

polyaxial locking technology.<br />

As a locking screw is inserted<br />

into a screw hole, the harder<br />

Grade 5 titanium screw<br />

forms its own threads within<br />

the Grade 2 titanium plate.<br />

Each hole also accepts<br />

non-locking screws, thus<br />

also allowing conventional<br />

non-locking screw fixation.<br />

With a single plate come<br />

many options. The genius of<br />

SmartLock is its simplicity.<br />

• Low Profile Plate Design<br />

Each <strong>VariAx</strong> <strong>Foot</strong> plate<br />

has a low profile (1−1.5mm<br />

thickness) to minimize soft<br />

tissue irritation. The screw<br />

heads also are designed for<br />

minimal head prominence,<br />

even when inserted at angles<br />

up to ±15°. This further<br />

reduces the risk of soft tissue<br />

irritation.<br />

Other Features<br />

• Compression and Locking in One Step<br />

• Deluxe or Basic Configurations<br />

• Modular System Design<br />

• Color Coding of Instruments and Implants<br />

The SmartLock Locking Technology is patented (US 6,322,562;<br />

DE 43 43 117; EP 1 143 867) by Professor Dietmar Wolter, Hamburg, Germany.<br />

Staple Fixation System<br />

Asnis III Cannulated Screws<br />

TwinFix Cannulated<br />

Compression Screw System<br />

AxSOS Distal Medial and<br />

Anterolateral Tibia Locking Plates

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!