Femoral & Tibial Nails - Stryker
Femoral & Tibial Nails - Stryker
Femoral & Tibial Nails - Stryker
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
T2<br />
<strong>Femoral</strong> & <strong>Tibial</strong> <strong>Nails</strong><br />
Best in Class Solutions for <strong>Femoral</strong><br />
and <strong>Tibial</strong> Fracture Treatment
T2<br />
<strong>Femoral</strong> Nail<br />
Reduced Inventory<br />
Precise Placement<br />
• Multiple End Cap<br />
Lengths<br />
• Easy Implant Removal<br />
• ONE Nail for Antegrade<br />
or Retrograde Insertion<br />
• ONE Nail for Left or<br />
Right<br />
• 5.0mm Screws Only<br />
Easy Insertion<br />
• Cannulated Design<br />
• Reamed or Unreamed<br />
Insertion over a<br />
3×1000mm Guide Wire<br />
• No Guide Wire<br />
Exchange Required<br />
Less Pain<br />
Potential*<br />
• Up to 10mm of Active<br />
Compression<br />
• Early Weight Bearing<br />
• Promotes Fracture<br />
Healing of Nonunions<br />
Stable Fixation<br />
• 5.0mm Cannulated<br />
Condyle Screws<br />
• Polyaxial Washers<br />
• Insertion over K-Wires<br />
• Up to 7mm of<br />
Mediolateral<br />
Interfragmentary<br />
Compression<br />
• End Cap tightens down<br />
on most Distal Locking<br />
Screw / Condyle Screw<br />
Providing Angular<br />
Stability
<strong>Tibial</strong> Nail<br />
Precise Placement<br />
• Multiple End Cap<br />
Lengths<br />
• Easy Implant Removal<br />
Stable Fixation<br />
• Multiplane Fixation<br />
• 5.0mm Screws for all<br />
9−15mm <strong>Nails</strong>**<br />
Less Pain Potential*<br />
• Up to 7mm of Active<br />
Compression<br />
• Early Weight Bearing<br />
• Promotes Fracture<br />
Healing of Non-Unions<br />
Easy Insertion<br />
• 10˚ Proximal Herzog<br />
Bend<br />
• 4˚ Distal Bend<br />
• Cannulated Design<br />
• Reamed or Unreamed<br />
Insertion over a<br />
3×800mm Guide Wire<br />
• No Guide Wire<br />
Exchange Required for<br />
all 9−15mm <strong>Nails</strong><br />
Extremely Distal<br />
Locking Holes<br />
• Two-Plane Fixation with<br />
Three Screws within<br />
25mm of the Nail End<br />
• Most Distal Hole is<br />
centered at 5mm from<br />
the Nail End<br />
* Thomas Mueckley, Oliver Gonschorek, Volker Buehren<br />
“Compression Nailing of Long Bones” Eur J Trauma 2003; 29:113-28<br />
** 8mm <strong>Tibial</strong> Nail uses 4.0mm Screws for Distal Locking
ormities<br />
Trauma, Extremities & Deformities<br />
Biologics<br />
Surgical Products<br />
Neuro & ENT<br />
<strong>Stryker</strong> Trauma GmbH<br />
Prof.-Küntscher-Straße 1–5<br />
D - 24232 Schönkirchen - Germany<br />
www.osteosynthesis.stryker.com<br />
The information presented in this brochure is intended to demonstrate a <strong>Stryker</strong> product. Always<br />
refer to the package insert, product label and/or user instructions before using any <strong>Stryker</strong> product.<br />
Surgeons must always rely on their own clinical judgment when deciding which products and<br />
techniques to use with their patients. Products may not be available in all markets. Product availability<br />
is subject to the regulatory or medical practices that govern individual markets. Please contact your<br />
<strong>Stryker</strong> representative if you have questions about the availability of <strong>Stryker</strong> products in your area.<br />
<strong>Stryker</strong> Corporation or its subsidiary owns the registered trademark: <strong>Stryker</strong><br />
<strong>Stryker</strong> Corporation or its subsidiary owns, uses or has applied for the following trademark: T2<br />
Literature Number: B1000042<br />
LOT C1406<br />
Copyright © 2006 <strong>Stryker</strong><br />
Printed in Germany