<strong>Pantera</strong> <strong>SA</strong> DS -21-0<strong>2M30</strong> and DS-22-0<strong>2M30</strong> User’s Manual 65<br />
Command<br />
Description<br />
Syntax Parameters Description<br />
34Hz. The actual frame rate will be<br />
within +/-13usec of 1/(entered<br />
value).<br />
set system gain ssg t i Sets the multiplier value for the<br />
given tap(s) to the specified digital<br />
gain value where the first<br />
parameter, t, is the tap number<br />
either 1 or 2, or 0 for all taps. The<br />
second parameter, f, is the valid<br />
multiplier range from 1x to 4x gain<br />
with 0.0001 resolution.<br />
set subtract background ssb t i Sets the value sent to the<br />
background subtractor module<br />
where the first parameter, t, is the<br />
tap number either 1 or 2, or 0 for all<br />
taps. The second parameter, the<br />
offset value, is 10-bits wide with a<br />
valid input of 0 to 1023.<br />
set video mode svm i Set video mode:<br />
0: Normal operating mode<br />
1: Test pattern Left side<br />
2: Test pattern Right side<br />
3: Test pattern Both sides<br />
4: Flip image Left side<br />
5: Flip image Left side Test pattern<br />
Left side<br />
6: Flip image Left side Test pattern<br />
Right side<br />
7: Flip image Left side Test pattern<br />
Both sides<br />
8: Flip image Right side<br />
9: Flip image Right side Test pattern<br />
Left side<br />
10:Flip image Right side Test pattern<br />
Right side<br />
11:Flip image Right side Test pattern<br />
Both sides<br />
12:Flip image Both sides<br />
13:Flip image Both sides Test<br />
pattern Left side<br />
14:Flip image Both sides Test<br />
pattern Right side<br />
15:Flip image Both sides Test<br />
pattern Both sides<br />
voltage verify vv Check the camera voltages and<br />
return OK or fail<br />
warning enable disable wed i i Read enable/disable status of all<br />
defined monitoring tasks.<br />
Optionally, the first value selects a<br />
monitoring task and the second<br />
value enables/disable the selected<br />
DAL<strong>SA</strong> 03-32-10150-01