<strong>Pantera</strong> <strong>SA</strong> DS -21-0<strong>2M30</strong> and DS-22-0<strong>2M30</strong> User’s Manual 31<br />

Guidelines and Rules for Setting the AOI<br />

When setting the area of interest, be aware that:<br />

• Changing the area of interest settings while the camera is operating in mode 2 will<br />

also change the set or ssf settings. Always re-enter set and ssf values after<br />

changing the AOI while operating in mode 2. To check settings, enter the command<br />

gcp. The help screen will display one of the following sets of messages:<br />

Condition<br />

set and ssf settings are<br />

correct and camera is<br />

running in exposure mode 2<br />

set and ssf settings are<br />

incorrect and camera is<br />

running is exposure mode 2<br />

camera is running in<br />

exposure mode 3, 4, or 6<br />

Help Screen Message<br />

<strong>Frame</strong> Rate Settings within round off error: YES<br />

Exposure Time within round off error: YES<br />

<strong>Frame</strong> Rate Settings within round off error: NO.<br />

Re-enter ssf cmd<br />

Exposure Time within round off error: NO. Reenter<br />

set cmd<br />

<strong>Frame</strong> Rate Settings with round off error: NA<br />

Exposure Time within round off error: NA<br />

• Changing the AOI while operating the camera in mode 6 can result in an invalid set<br />

result. Always re-enter your set value after changing the AOI when operating in<br />

mode 6.<br />

• The camera will ignore any EXSYNC signals that occur quicker than the readout rate.<br />

• The exposure time setting cannot be greater than the frame time. The minimum<br />

frame time cannot be less than the readout time. If either of these conditions are<br />

violated, the camera will automatically adjust these settings.<br />

• If you are using binning, the window start/end values will be rounded using the<br />

following equations:<br />

Binning Start Value = INT [(Input Value-1)/Binning Factor] x Binning Factor +1<br />

Binning End Value = [INT {(Input Value-1)/Binning Factor} x Binning Factor +1]+<br />

(Binning Factor –1)<br />

• If you are using the color (DS-22-0<strong>2M30</strong>) <strong>2M30</strong>, the resolution of the color filter array<br />

Bayer Pattern (2x2) restricts the size and position of the AOI. You must specify an<br />

odd number for the start row and an even number for the end row. If you specify an<br />

even number for the start row, the Bayer pattern is reversed and the resulting image<br />

is corrupted.<br />

Timing Considerations<br />

When operating the camera in either exposure mode 2 or exposure mode 6, the camera<br />

timing may be altered.<br />

The electronic shutter cannot fire while the sensor is dumping unwanted data (regions 3<br />

and 5 in Figure 15). The electronic shutter will fire as soon as the dump is complete and<br />

the value set for the exposure time will be altered accordingly. You will not be told<br />

explicitly that the exposure time has been altered, but you can obtain the new value by<br />

entering the gcp command.<br />