DS-24-0<strong>2M30</strong> and DS-25-0<strong>2M30</strong> <strong>User</strong>’s <strong>Manual</strong> 60<br />

Command<br />

Description<br />

Syntax Parameters Description<br />

set subtract background ssb t i Sets the value sent to the<br />

background subtractor module<br />

where the first parameter, t, is the<br />

tap number either 1 or 2, or 0 for<br />

all taps. The second parameter,<br />

the offset value, is 10-bits wide<br />

with a valid input of 0 to 1023.<br />

set video mode svm i Set video mode:<br />

0: Normal operating mode<br />

1: Test pattern Left side<br />

2: Test pattern Right side<br />

3: Test pattern Both sides<br />

4: Flip image Left side<br />

5: Flip image Left side Test<br />

pattern Left side<br />

6: Flip image Left side Test<br />

pattern Right side<br />

7: Flip image Left side Test<br />

pattern Both sides<br />

8: Flip image Right side<br />

9: Flip image Right side Test<br />

pattern Left side<br />

10:Flip image Right side Test<br />

pattern Right side<br />

11:Flip image Right side Test<br />

pattern Both sides<br />

12:Flip image Both sides<br />

13:Flip image Both sides Test<br />

pattern Left side<br />

14:Flip image Both sides Test<br />

pattern Right side<br />

15:Flip image Both sides Test<br />

pattern Both sides<br />

voltage verify vv Check the camera voltages and<br />

return OK or fail<br />

warning enable disable wed i i Read enable/disable status of all<br />

defined monitoring tasks.<br />

Optionally, the first value selects a<br />

monitoring task and the second<br />

value enables/disable the selected<br />

task. See section 3.13 Monitoring<br />

Tasks for a list of tasks.<br />

write output LUT wol i Store the current active output<br />

LUT to nonvolatile memory. You<br />

can store up to two separate<br />

output LUTs. The parameter, i, is<br />

the table number, either 1 to 2.<br />

See Appendix C for more<br />

information on using look up<br />

tables.<br />