DS-24-0<strong>2M30</strong> and DS-25-0<strong>2M30</strong> <strong>User</strong>’s <strong>Manual</strong> 56<br />
Informal Message Codes<br />
Code Description Suggested Cause<br />
8 INFO: DSP configuration file missing<br />
or corrupt<br />
16 INFO: Serial communication failure<br />
while accessing external ADC chip<br />
Reported from boot process, only if<br />
DSP configuration fails (possible<br />
cause)<br />
Reported from boot process if<br />
communication verification fails with<br />
external ADC chip (camera voltage<br />
measurement, SPI)<br />
B6 Commands<br />
Monitoring Task Message Codes<br />
Code Description Suggested Cause<br />
1 WARNING: One or more voltages out<br />
of specification<br />
At least one of voltages is out of<br />
specification<br />
16 Current analog gain setting is out of<br />
specification<br />
The following table lists all of the commands available to the camera user.<br />
Parameters:<br />
i = integer<br />
f = float<br />
t = tap selector<br />
q = window sequence<br />
[ ]= optional parameter<br />
Table 19: All Available Commands<br />
Command<br />
Description<br />
Syntax Parameters Description<br />
display input LUT dil t i i Retrieve and display the contents of<br />
the input LUT. The first parameter,<br />
t, is the tap number either 1 or 2, or<br />
0 for all taps. The second parameter,<br />
i, is the first address to be read out<br />
in a range from 0 to 1023. The third<br />
parameter, i, is the last address to<br />
be read out in a range from 0 to<br />
1023.<br />
See Appendix C for more<br />
information on using look up tables.<br />
display output LUT dol i i Retrieve and display the contents of<br />
the output LUT where the first<br />
parameter, i, is the first address to<br />
be read out in a range from 0 to<br />
1023 and the second parameter, i,<br />
is the last address to be read out in a<br />
range from 0 to 1023.<br />
See Appendix C for more<br />
information on using look up tables.<br />
enable input LUT eil i Enable or disable the input LUTs.<br />
When disabled, the video path is<br />
routed around the active LUTs, but<br />
the set values remain unchanged<br />
where i is:<br />
0: Disable input LUT, default<br />
1: Enable input LUT<br />
See Appendix C for more<br />