DS-24-0<strong>2M30</strong> and DS-25-0<strong>2M30</strong> <strong>User</strong>’s <strong>Manual</strong> 56<br />

Informal Message Codes<br />

Code Description Suggested Cause<br />

8 INFO: DSP configuration file missing<br />

or corrupt<br />

16 INFO: Serial communication failure<br />

while accessing external ADC chip<br />

Reported from boot process, only if<br />

DSP configuration fails (possible<br />

cause)<br />

Reported from boot process if<br />

communication verification fails with<br />

external ADC chip (camera voltage<br />

measurement, SPI)<br />

B6 Commands<br />

Monitoring Task Message Codes<br />

Code Description Suggested Cause<br />

1 WARNING: One or more voltages out<br />

of specification<br />

At least one of voltages is out of<br />

specification<br />

16 Current analog gain setting is out of<br />

specification<br />

The following table lists all of the commands available to the camera user.<br />

Parameters:<br />

i = integer<br />

f = float<br />

t = tap selector<br />

q = window sequence<br />

[ ]= optional parameter<br />

Table 19: All Available Commands<br />

Command<br />

Description<br />

Syntax Parameters Description<br />

display input LUT dil t i i Retrieve and display the contents of<br />

the input LUT. The first parameter,<br />

t, is the tap number either 1 or 2, or<br />

0 for all taps. The second parameter,<br />

i, is the first address to be read out<br />

in a range from 0 to 1023. The third<br />

parameter, i, is the last address to<br />

be read out in a range from 0 to<br />

1023.<br />

See Appendix C for more<br />

information on using look up tables.<br />

display output LUT dol i i Retrieve and display the contents of<br />

the output LUT where the first<br />

parameter, i, is the first address to<br />

be read out in a range from 0 to<br />

1023 and the second parameter, i,<br />

is the last address to be read out in a<br />

range from 0 to 1023.<br />

See Appendix C for more<br />

information on using look up tables.<br />

enable input LUT eil i Enable or disable the input LUTs.<br />

When disabled, the video path is<br />

routed around the active LUTs, but<br />

the set values remain unchanged<br />

where i is:<br />

0: Disable input LUT, default<br />

1: Enable input LUT<br />

See Appendix C for more<br />

DALSA 03-32-10157-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!