DS-24-02M30 and DS-25-02M30 User’s Manual 18 3.2 Communications Protocol Overview Serial Protocol Defaults: 8 data bits 1 stop bit No parity No flow control 9.6Kbps Camera does not echo characters 3.3 Command Format 3.4 Startup When entering commands, remember that: A carriage return (CR) ends each command. The linefeed character is ignored. Values in square brackets are optional. The camera will answer each command with either a carriage return and line feed followed by "OK >" or "Error x: Error Message >". The ">" is always the last character sent by the camera. The following parameter conventions are used: t = tap id i = integer value f = real number s = string [ ] = optional parameter When the camera is first started, it must perform several actions before it is ready for imaging. This startup routine takes approximately 15 seconds, and follows this sequence: 1. Initializes the camera and all internal hardware. 2. Loads the last settings saved to non-volatile memory. 3. Restores user settings if previously saved, otherwise factory settings. 4. Performs a memory test and voltage test and reports an error if any occurred. After this startup sequence has completed, the camera will return either the prompt "OK>" if no error occurred, or an error code if a problem has been discovered. 3.5 Saving and Restoring Settings As illustrated in Figure 9, there are three type of camera settings: factory settings, user settings, and current session settings. DALSA 03-32-10157-02
DS-24-02M30 and DS-25-02M30 User’s Manual 19 Figure 9: Saving and Restoring Overview Factory Settings User Settings / EEROM restore Current Session w rite / restore Factory Settings On first initialization, the camera operates using the factory settings. You can restore the original factory settings at any time using the command rfs. User Settings You can save or restore your user settings to non-volatile memory using the following commands: • To save all current user settings to EEROM, use the command wus. The camera will automatically restore the saved user settings when powered up. • To restore the last saved user settings, use the command rus. Current Session Settings These are the current operating settings of your camera. These settings are stored in the camera’s volatile memory and will not be restored once you power down your camera. To save these settings to non-volatile memory, use the command wus. 3.6 Setting Baud Rate To set the speed of the camera serial communication port, use the command: Syntax: Syntax Elements: sbr i i Baud rate. Available baud rates are: 9600 (Default), 19200, 57600, and 115200. Notes: Power-on rate is always 9600 baud. The rc (reset camera) command will not reset the camera to the power-on baud rate. Example: sbr 57600 DALSA 03-32-10157-02
- Page 1 and 2: Pantera SA 2M30 1920 x 1080 Stop Ac
- Page 3 and 4: DS-24-02M30 and DS-25-02M30 User’
- Page 5 and 6: DS-24-02M30 and DS-25-02M30 User’
- Page 7 and 8: DS-24-02M30 and DS-25-02M30 User’
- Page 9 and 10: DS-24-02M30 and DS-25-02M30 User’
- Page 11 and 12: DS-24-02M30 and DS-25-02M30 User’
- Page 13 and 14: DS-24-02M30 and DS-25-02M30 User’
- Page 15 and 16: DS-24-02M30 and DS-25-02M30 User’
- Page 17: DS-24-02M30 and DS-25-02M30 User’
- Page 21 and 22: DS-24-02M30 and DS-25-02M30 User’
- Page 23 and 24: DS-24-02M30 and DS-25-02M30 User’
- Page 25 and 26: DS-24-02M30 and DS-25-02M30 User’
- Page 27 and 28: DS-24-02M30 and DS-25-02M30 User’
- Page 29 and 30: DS-24-02M30 and DS-25-02M30 User’
- Page 31 and 32: DS-24-02M30 and DS-25-02M30 User’
- Page 33 and 34: DS-24-02M30 and DS-25-02M30 User’
- Page 35 and 36: DS-24-02M30 and DS-25-02M30 User’
- Page 37 and 38: DS-24-02M30 and DS-25-02M30 User’
- Page 39 and 40: DS-24-02M30 and DS-25-02M30 User’
- Page 41 and 42: DS-24-02M30 and DS-25-02M30 User’
- Page 43 and 44: DS-24-02M30 and DS-25-02M30 User’
- Page 45 and 46: DS-24-02M30 and DS-25-02M30 User’
- Page 47 and 48: DS-24-02M30 and DS-25-02M30 User’
- Page 49 and 50: DS-24-02M30 and DS-25-02M30 User’
- Page 51 and 52: DS-24-02M30 and DS-25-02M30 User’
- Page 53 and 54: DS-24-02M30 and DS-25-02M30 User’
- Page 55 and 56: DS-24-02M30 and DS-25-02M30 User’
- Page 57 and 58: DS-24-02M30 and DS-25-02M30 User’
- Page 59 and 60: DS-24-02M30 and DS-25-02M30 User’
- Page 61 and 62: DS-24-02M30 and DS-25-02M30 User’
- Page 63 and 64: DS-24-02M30 and DS-25-02M30 User’
- Page 65 and 66: DS-24-02M30 and DS-25-02M30 User’
- Page 67 and 68: Output DS-24-02M30 and DS-25-02M30
DS-24-0<strong>2M30</strong> and DS-25-0<strong>2M30</strong> <strong>User</strong>’s <strong>Manual</strong> 18<br />
3.2 Communications Protocol Overview<br />
Serial Protocol Defaults:<br />
<br />
<br />
<br />
<br />
<br />
<br />
8 data bits<br />
1 stop bit<br />
No parity<br />
No flow control<br />
9.6Kbps<br />
Camera does not echo characters<br />
3.3 Command Format<br />
3.4 Startup<br />
When entering commands, remember that:<br />
<br />
<br />
<br />
<br />
A carriage return (CR) ends each command. The linefeed character is ignored.<br />
Values in square brackets are optional.<br />
The camera will answer each command with either a carriage return and line<br />
feed followed by "OK >" or "Error x: Error Message >". The ">" is always the<br />
last character sent by the camera.<br />
The following parameter conventions are used:<br />
t = tap id<br />
i = integer value<br />
f = real number<br />
s = string<br />
[ ] = optional parameter<br />
When the camera is first started, it must perform several actions before it is ready for<br />
imaging. This startup routine takes approximately 15 seconds, and follows this sequence:<br />
1. Initializes the camera and all internal hardware.<br />
2. Loads the last settings saved to non-volatile memory.<br />
3. Restores user settings if previously saved, otherwise factory settings.<br />
4. Performs a memory test and voltage test and reports an error if any occurred.<br />
After this startup sequence has completed, the camera will return either the prompt<br />
"OK>" if no error occurred, or an error code if a problem has been discovered.<br />
3.5 Saving and Restoring Settings<br />
As illustrated in Figure 9, there are three type of camera settings: factory settings, user<br />
settings, and current session settings.<br />
DALSA 03-32-10157-02