DS-24-0<strong>2M30</strong> and DS-25-0<strong>2M30</strong> <strong>User</strong>’s <strong>Manual</strong> 14<br />

Input Signals, Camera Link<br />

i<br />

The camera accepts control inputs through the Camera Link MDR26F connector.<br />

The camera ships in internal sync, internal programmed integration (exposure mode 2).<br />

EXSYNC (Triggers Line Readout)<br />

<strong>Frame</strong> rate can be set internally using the serial interface. The external control signal<br />

EXSYNC is optional and enabled through the serial interface. This camera uses the falling<br />

edge of EXSYNC to trigger line readout. Section 3.8 Setting <strong>Frame</strong> Rate, Exposure Time,<br />

and Exposure Mode details how to set frame times, exposure times, and camera modes.<br />

Output Signals, Camera Link<br />

IMPORTANT:<br />

This camera’s data<br />

should be sampled on<br />

the rising edge of<br />

STROBE.<br />

These signals indicate when data is valid, allowing you to clock the data from the camera<br />

to your acquisition system. These signals are part of the Camera Link configuration and<br />

you should refer to the DALSA Camera Link Implementation Road Map, available at<br />

http://vfm.dalsa.com/, for the standard location of these signals.<br />

Clocking Signal<br />

LVAL (high)<br />

DVAL (high)<br />

STROBE (rising edge)<br />

FVAL (high)<br />

Indicates<br />

Outputting valid line<br />

Valid data<br />

Valid data<br />

Outputting valid frame<br />

For a Camera Link reference and timing definitions refer to Appendix A on page 43.<br />

2.2.3 Power Connector<br />

Figure 8: Hirose 6-pin Circular Male—Power Connector<br />

Hirose 6-pin Circular Male<br />

1 6<br />

2 5<br />

3 4<br />

Mat ing Par t: HIRO SE<br />

HR10A-7P-6S<br />

Table 7: Hirose Pin Description<br />

Pin Description Pin Description<br />

1 +11 to +25V 4 GND<br />

2 +11 to +25V 5 GND<br />

3 +11 to +25V 6 GND<br />

The camera requires a single voltage input (+11V to +25V). The camera meets all<br />

performance specifications using standard switching power supplies, although wellregulated<br />

linear supplies provide optimum performance. When setting up the camera’s<br />

power supplies follow these guidelines:<br />

• Protect the camera with a fast-blow fuse between power supply and camera.<br />

• Do not use the shield on a multi-conductor cable for ground.<br />

• Keep leads as short as possible to reduce voltage drop.<br />

• Use high-quality linear supplies to minimize noise.<br />

Note: Performance specifications are not guaranteed if your power supply does not meet<br />