<strong>Spyder</strong> 3 <strong>GigE</strong> User’s <strong>Manual</strong><br />

9<br />

Operating Specifications (12 bit values, Flat Field Correction enabled)<br />

Specification Unit -10dB 0dB +10dB<br />

Min<br />

Typ<br />

Max<br />

Min<br />

Typ<br />

Max<br />

Min<br />

Typ<br />

Max<br />

Notes<br />

PRNU ECD<br />

Uncorrected Local<br />

Uncorrected Global<br />

Corrected Local<br />

Corrected Global<br />

%<br />

%<br />

DN p-p<br />

DN p-p<br />

8.5%<br />

10%<br />

32<br />

32<br />

8.5%<br />

10%<br />

32<br />

32<br />

8.5%<br />

10%<br />

64<br />

64<br />

1<br />

PRNU ECE<br />

Uncorrected Local<br />

Uncorrected Global<br />

Corrected Local<br />

Corrected Global<br />

SEE (calculated)<br />

<strong>Dual</strong> line<br />

Single line<br />

NEE (calculated)<br />

<strong>Dual</strong> line<br />

Single line<br />

Sat. Output<br />

Amplitude<br />

%<br />

%<br />

DN p-p<br />

DN p-p<br />

nJ/cm 2<br />

pJ/cm 2<br />

6.75<br />

13.5<br />

13.6<br />

27.2<br />

8.5%<br />

10%<br />

80<br />

80<br />

2.14<br />

4.29<br />

10.3<br />

20.8<br />

DN 3968±80<br />

DC Offset DN 96 160 336<br />

Test conditions unless otherwise noted:<br />

• CCD Pixel Rate: 40 MHz per sensor tap<br />

• <strong>Line</strong> Rate: 5000 Hz<br />

• Nominal Gain setting unless otherwise specified<br />

12%<br />

12%<br />

208<br />

208<br />

0.68<br />

1.35<br />

10.2<br />

20.4<br />

• Light Source: Broadband Quartz Halogen, 3250k, with 750 nm highpass filter<br />

installed<br />

• Ambient test temperature 25 °C<br />

• Unless specified, all values are referenced at 12 bit<br />

• Exposure mode disabled.<br />

• Unless specified, dual line mode.<br />

37%<br />

37%<br />

752<br />

752<br />

Notes<br />

1. PRNU measured at 50% SAT.<br />

DALSA 03-032-10158-06