<strong>Spyder</strong> 3 <strong>GigE</strong> User’s <strong>Manual</strong><br />

89<br />

A4.7 Returning <strong>Camera</strong> Settings<br />

Returning All <strong>Camera</strong> Settings with the <strong>Camera</strong> Parameter<br />

Screen<br />

The camera parameter (gcp) screen returns all of the camera’s current settings. The table<br />

below lists all of the gcp screen settings.<br />

To read all current camera settings, use the command:<br />

Syntax:<br />

gcp<br />

GCP Screen<br />

Description<br />

GENERAL CAMERA SETTINGS<br />

<strong>Camera</strong> Model No.: SG-10-02K80 <strong>Camera</strong> model number.<br />

<strong>Camera</strong> Serial No.: xxxxxxxxx <strong>Camera</strong> serial number.<br />

Firmware Version: xx-xx-xxxxx-xx Firmware design<br />

revision number.<br />

CCI Version: xx-xxx-xxxxx-xx CCI version number.<br />

FPGA Version: xxx.xx FPGA revision number.<br />

UART Baud Rate: 115200 Serial communication<br />

connection speed set<br />

with the 120Hsbr command.<br />

See 297HSetting Baud Rate<br />

on page 298H54 for details.<br />

<strong>Dual</strong> Scan Mode: High Sensitivity Current sensitivity<br />

mode set with the 121Hshm<br />

command. See section<br />

299HA1.1 Sensitivity Mode<br />

for details.<br />

<strong>Camera</strong> Mode: 2 taps, 12 bits Current bit depth<br />

setting set with the sdm<br />

command. Refer to<br />

section 300HA1.3 Setting the<br />

Bit Depth for details.<br />

Readout Mode: Off Current readout mode<br />

status. Set using the srm<br />

command.<br />

Exposure Mode: 7 Current exposure mode<br />

value set with the 122Hsem<br />

command. See section<br />

301HA1.4 Exposure Mode,<br />

Readout Mode, <strong>Line</strong><br />

Rate and Exposure<br />

Time for details.<br />

SYNC Frequency: 5000.00 Hz Current line rate. Value<br />

is set with the 123Hssf<br />

command. See section<br />

302HA1.4 Exposure Mode,<br />

Readout Mode, <strong>Line</strong><br />

Rate and Exposure<br />

Time for details.<br />

DALSA 03-032-10158-06