Location Value Description<br />
9 Pixels above threshold (7…0)<br />
10 Pixels above threshold<br />
(15…8)<br />
11 Pixels below threshold (7…0)<br />
12 Pixels below threshold (15…8)<br />
Monitor these values (either above or<br />
below threshold) and adjust camera<br />
digital gain and background subtract to<br />
maximize scene contrast. This provides a<br />
basis for automatic gain control (AGC)<br />
13 Differential line sum (7..0)<br />
14 Differential line sum (15…8)<br />
15 Differential line sum (23…16)<br />
Use these values to focus the camera.<br />
Generally, the greater the sum the greater<br />
the image contrast and better the focus.<br />
16 Differential line sum (31…24)<br />
Setting Thresholds<br />
Setting an Upper Threshold<br />
Purpose:<br />
Syntax:<br />
Syntax Elements:<br />
Sets the upper threshold limit to report in the end-of-line<br />
sequence.<br />
sut i<br />
i<br />
Upper threshold limit in range from 0 to 4095.<br />
Notes: • LVAL is not high during the end-of-line statistics.<br />
Related Commands: • 106Hels,<br />
107Hslt<br />
Example: sut 1024<br />
Setting a Lower Threshold<br />
Purpose:<br />
Syntax:<br />
Syntax Elements:<br />
Sets the lower threshold limit to report in the end-of-line<br />
sequence.<br />
slt i<br />
i<br />
Upper threshold limit in range from 0 to 4095.<br />
Notes: • LVAL is not high during the end-of-line statistics.<br />
Related Commands: • 108Hels,<br />
109Hsut<br />
Example: slt 1024<br />