78<br />
<strong>Spyder</strong> 3 <strong>GigE</strong> User <strong>Manual</strong><br />
Notes: • When subtracting a digital value from the digital video signal<br />
the output can no longer reach its maximum. Use the 98Hssg<br />
command to correct for this where:<br />
Related Commands:<br />
100Hssg<br />
Example ssb 0 25<br />
ssg value =<br />
max output value<br />
max output value ‐ ssb value<br />
See the following section for details on the 99Hssg command.<br />
Setting Digital System Gain<br />
Purpose:<br />
Syntax:<br />
Syntax Elements:<br />
Improves signal output swing after a background subtract. When<br />
subtracting a digital value from the digital video signal, using the<br />
101Hssb command, the output can no longer reach its maximum. Use<br />
this command to correct for this where:<br />
ssg value =<br />
max output value<br />
max output value ‐ ssb value<br />
ssg t i<br />
t<br />
i<br />
Tap selection. Allowable range is 1 to 2, or 0 for all taps.<br />
Related Commands:<br />
103Hssb<br />
Gain setting. The gain ranges are 0 to 65535. The digital<br />
video values are multiplied by this value where:<br />
i<br />
Digital Gain=<br />
4096<br />
Use this command in conjunction with the 102Hssb<br />
command.<br />
Example: ssg 1 15<br />
03-032-10158-06 DALSA