<strong>Spyder</strong> 3 <strong>GigE</strong> User <strong>Manual</strong><br />

Purpose:<br />

Syntax:<br />

Syntax Elements:<br />

Instead of manually setting the analog gain to a specific value, the<br />

camera can determine appropriate gain values. This command<br />

calculates and sets the analog gain according to the algorithm<br />

determined by the first parameter.<br />

ccg i t i<br />

i<br />

t<br />

Calibration algorithm to use.<br />

1 = This algorithm adjusts analog gain so that 8% to 13% of<br />

tap region of interest (ROI) pixels are above the specified<br />

target value.<br />

2 = This algorithm adjusts analog gain so that the average<br />

pixel value in tap’s ROI is equal to the specified target<br />

value.<br />

3 = This algorithm adjusts digital gain so that the average<br />

pixel value in tap’s ROI is equal to the specified target.<br />

4 = This algorithm adjusts the analog gain so that the peak<br />

tap ROI pixels are adjusted to the specified target.<br />

Tap value. Use 0 for all taps or 1 to 2 for individual tap<br />

selection if you are using the two tap model.<br />

i<br />

Calculation target value in a range from 1024 to 4055DN<br />

(12 bit LSB).<br />

Notes: • This function requires constant light input while executing.<br />

• If very few tap pixels are within the ROI, gain calculation<br />

may not be optimal.<br />

• When all taps are selected, taps outside of the ROI are set to<br />

the average gain of the taps that are within the ROI.<br />

• Perform analog gain algorithms before performing FPN and<br />

PRNU calibration.<br />

• All digital settings affect the analog gain calibration. If you<br />

do not want the digital processing to have any effect on the<br />

camera gain calibration, then turn off all digital settings by<br />

sending the commands: 73Hsdo 0 0, 74Hepc 0 0, 75Hssb 0 0, and<br />

76Hssg 0 4096<br />

Example: ccg 2 0 3040<br />

Related Commands:<br />

77Hsag, 78Hssg<br />

Setting Analog Offset<br />