62<br />
<strong>Spyder</strong> 3 <strong>GigE</strong> User <strong>Manual</strong><br />
i<br />
Applies to Modes 2 and<br />
7<br />
Setting the <strong>Line</strong> Rate<br />
Purpose:<br />
Syntax:<br />
Sets the camera’s line rate in Hz. <strong>Camera</strong> must be operating in<br />
exposure mode 2 or 7.<br />
ssf f<br />
Syntax Elements:<br />
i<br />
Desired line rate in Hz. Allowable values are:<br />
1k 1 tap: 300-36000 Hz<br />
1k 2 tap: 300-68000 Hz<br />
2k 1 tap: 300-18500 Hz<br />
2k 2 tap: 300-36000 Hz<br />
Notes: • To read the current line frequency, use the command 29Hgcp or<br />
30Hget ssf.<br />
• If you enter an invalid line rate frequency, an error message is<br />
returned.<br />
Related Commands:<br />
31Hsem, 32Hset<br />
Example: ssf 10000<br />
i<br />
Applies to Modes 2 and<br />
8<br />
Setting the Exposure Time<br />
Purpose:<br />
Syntax:<br />
Sets the camera’s exposure time is µs. <strong>Camera</strong> must be operating in<br />
mode 2, 6, or 8.<br />
set f<br />
Syntax Elements:<br />
i<br />
Desired exposure time in µs. Allowable range is 3 to 3300µs.*<br />
Notes: • To read the current line frequency, use the command 33Hgcp or<br />
34Hget set.<br />
• If you enter an invalid line rate frequency, an error message is<br />
returned.<br />
• *The exposure time range is based on the current line rate.<br />
• To determine the maximum exposure time allowed for the<br />
current line rate, use the command get ger.<br />
Related Commands:<br />
35Hsem, 36Hssf<br />
Example: set 400.5<br />
03-032-10158-06 DALSA