Spyder 3 Camera User's Manual GigE Dual Line - Frame Grabbers
Spyder 3 Camera User's Manual GigE Dual Line - Frame Grabbers
Spyder 3 Camera User's Manual GigE Dual Line - Frame Grabbers
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Spyder</strong> 3 <strong>GigE</strong> User’s <strong>Manual</strong><br />
59<br />
Mode 3: External Trigger with Maximum Exposure<br />
<strong>Line</strong> rate is set by the period of the external trigger pulses. The falling edge of the external<br />
trigger marks the beginning of the exposure.<br />
Example 2: <strong>Line</strong> Rate is set by External Trigger Pulses.<br />
<strong>Line</strong> Period<br />
<strong>Line</strong> Period<br />
Readout<br />
Readout<br />
EXSYNC<br />
Exposure Time<br />
Exposure Time<br />
Falling Edge<br />
Ignored During<br />
Readou<br />
t<br />
Mode 4: Smart EXSYNC, External <strong>Line</strong> Rate and Exposure Time<br />
Falling Edge<br />
Ignored During<br />
Readout<br />
In this mode, EXSYNC sets both the line period and the exposure time. The rising edge of<br />
EXSYNC marks the beginning of the exposure and the falling edge initiates readout.<br />
Example 3: Trigger Period is Repetitive and Greater than Read Out Time.<br />
<strong>Line</strong> Period<br />
Readout<br />
<strong>Line</strong> Period<br />
Readout<br />
EXSYNC<br />
CR=Charge Reset<br />
EXSYNC Falling<br />
Edge ignored<br />
during readout<br />
EXSYNC Falling<br />
Edge ignored<br />
during readout<br />
Mode 5: External <strong>Line</strong> Rate (EXSYNC) and External Pixel Reset (PRIN)<br />
In this mode, the falling edge of EXSYNC sets the line period and the rising edge of PRIN<br />
sets the start of exposure time.<br />
Figure 20: EXSYNC controls <strong>Line</strong> Period and PRIN controls Exposure Time<br />
<strong>Line</strong> Period<br />
Readou<br />
t<br />
<strong>Line</strong> Period<br />
<strong>Line</strong> Period<br />
Readou<br />
t<br />
EXSYNC<br />
PRIN<br />
cr=Charge Reset<br />
DALSA 03-032-10158-06