40 Spyder 3 GigE User Manual The focal point is the point at which the image of an infinitely distant object is brought to focus. The effective focal length (f′) is the distance from the second principal point to the second focal point. The back focal length (BFL) is the distance from the image side of the lens surface to the second focal point. The object distance (OD) is the distance from the first principal point to the object. Figure 19: Primary Points in a Lens System Magnification and Resolution The magnification of a lens is the ratio of the image size to the object size: m h ′ where m is the magnification, h’ is the image height = h (pixel size) and h is the object height (desired object resolution size). By similar triangles, the magnification is alternatively given by: f′ m = OD These equations can be combined to give their most useful form: h′ f′ = h OD This is the governing equation for many object and image plane parameters. Example: An acquisition system has a 512 x 512 element, 10m pixel pitch area scan camera, a lens with an effective focal length of 45mm, and requires that 100μm in the object space correspond to each pixel in the image sensor. Using the preceding equation, the object distance must be 450mm (0.450m). 10μm 45mm = OD = 450mm( 0. 450m) 100μm OD 4.3 Electrical Interface The Spyder 3 GigE cameras have been designed for EMC compliance. The test setup has been verified to the following EMC standards: • CISPR-11:2004 • EN 55011:2003 • EN 61326:2002 To achieve EMC compliance, follow these specific guidelines: 03-032-10158-06 DALSA
Spyder 3 GigE User’s Manual 41 • Ensure that all cable shields have 360° electrical connection to the connector. • Fasten and secure all connectors. The EMC compliance is achieved with the use of shielded CAT5e or CAT6 Ethernet cables Shielded cable suppliers The following is a partial list of cable suppliers carrying cables that meet the compliance requirements: • http://www.systemax.com/divisions.htm • http://www.cablestogo.com • http://www.globalsources.com DALSA 03-032-10158-06
- Page 1 and 2: Spyder 3 Camera User’s Manual Gig
- Page 3 and 4: Spyder 3 GigE User’s Manual 3 Con
- Page 5 and 6: Spyder 3 GigE User’s Manual 5 Int
- Page 7 and 8: Spyder 3 GigE User’s Manual 7 •
- Page 9 and 10: Spyder 3 GigE User’s Manual 9 Ope
- Page 11 and 12: Spyder 3 GigE User’s Manual 11 Fi
- Page 13 and 14: Spyder 3 GigE User’s Manual 13 1.
- Page 15 and 16: Spyder 3 GigE User’s Manual 15 Ch
- Page 17 and 18: Spyder 3 GigE User’s Manual 17 2
- Page 19 and 20: Spyder 3 GigE User’s Manual 19 4
- Page 21 and 22: Spyder 3 GigE User’s Manual 21 4.
- Page 23 and 24: Spyder 3 GigE User’s Manual 23 DA
- Page 25 and 26: Spyder 3 GigE User’s Manual 25 2.
- Page 27 and 28: Spyder 3 GigE User’s Manual 27 Fi
- Page 29 and 30: Spyder 3 GigE User’s Manual 29 Ta
- Page 31 and 32: Spyder 3 GigE User’s Manual 31 3
- Page 33 and 34: Spyder 3 GigE User’s Manual 33
- Page 35 and 36: Spyder 3 GigE User’s Manual 35 Vi
- Page 37 and 38: Spyder 3 GigE User’s Manual 37 4
- Page 39: Spyder 3 GigE User’s Manual 39 4.
- Page 43 and 44: Spyder 3 GigE User’s Manual 43 5
- Page 45 and 46: Spyder 3 GigE User’s Manual 45 5.
- Page 47 and 48: Spyder 3 GigE User’s Manual 47 6
- Page 49 and 50: Spyder 3 GigE User’s Manual 49 Ca
- Page 51 and 52: Spyder 3 GigE User’s Manual 51 en
- Page 53 and 54: Spyder 3 GigE User’s Manual 53 Ap
- Page 55 and 56: Spyder 3 GigE User’s Manual 55 Pa
- Page 57 and 58: Spyder 3 GigE User’s Manual 57 A1
- Page 59 and 60: Spyder 3 GigE User’s Manual 59 Mo
- Page 61 and 62: Spyder 3 GigE User’s Manual 61 Se
- Page 63 and 64: Spyder 3 GigE User’s Manual 63 A1
- Page 65 and 66: ccg, Spyder 3 GigE User’s Manual
- Page 67 and 68: Spyder 3 GigE User’s Manual 67 To
- Page 69 and 70: Spyder 3 GigE User’s Manual 69 Pu
- Page 71 and 72: Spyder 3 GigE User’s Manual 71 Fo
- Page 73 and 74: Spyder 3 GigE User’s Manual 73 Di
- Page 75 and 76: Spyder 3 GigE User’s Manual 75 Pe
- Page 77 and 78: Spyder 3 GigE User’s Manual 77 cp
- Page 79 and 80: Spyder 3 GigE User’s Manual 79 Re
- Page 81 and 82: Spyder 3 GigE User’s Manual 81 Lo
- Page 83 and 84: Spyder 3 GigE User’s Manual 83 A3
- Page 85 and 86: Spyder 3 GigE User’s Manual 85 1
- Page 87 and 88: Spyder 3 GigE User’s Manual 87 Re
- Page 89 and 90: Spyder 3 GigE User’s Manual 89 A4
<strong>Spyder</strong> 3 <strong>GigE</strong> User’s <strong>Manual</strong><br />
41<br />
• Ensure that all cable shields have 360° electrical connection to the connector.<br />
• Fasten and secure all connectors.<br />
The EMC compliance is achieved with the use of shielded CAT5e or CAT6 Ethernet<br />
cables<br />
Shielded cable suppliers<br />
The following is a partial list of cable suppliers carrying cables that meet the compliance<br />
requirements:<br />
• http://www.systemax.com/divisions.htm<br />
• http://www.cablestogo.com<br />
• http://www.globalsources.com<br />
DALSA 03-032-10158-06