Spyder 3 Camera User's Manual GigE Dual Line - Frame Grabbers

Spyder 3 Camera User's Manual GigE Dual Line - Frame Grabbers Spyder 3 Camera User's Manual GigE Dual Line - Frame Grabbers

10.05.2014 Views

102 Spyder 3 GigE User Manual Mnemonic Syntax Parameters Description set video mode svm i Switch between normal video mode and camera test patterns: 0: Normal video mode 1: Camera test pattern 2: Camera test pattern update gain reference ugr Changes 0dB gain to equal the current analog gain value set with the sag command. verify temperature vt Check the internal temperature of the camera verify voltage vv Check the camera’s input voltages and return OK or fail write FPN coefficients wfc i Write all current FPN coefficients to EEROM where i is: 1 = FPN coefficient set one 2 = FPN coefficient set two 3 = FPN coefficient set one 4 = FPN coefficient set two write PRNU coeffs wpc i Write all current PRNU coefficients to EEROM where i is: 1 = PRNU coefficient set one 2 = PRNU coefficient set two 3 = PRNU coefficient set one 4 = PRNU coefficient set two write user settings wus Write all of the user settings to EEROM. 03-032-10158-06 DALSA

Spyder 3 GigE User’s Manual 103 A5 Error Handling The following table lists warning and error messages and provides a description and possible cause. Warning messages are returned when the camera cannot meet the full value of the request; error messages are returned when the camera is unable to complete the request. Table 15: Warning and Error Messages Message Description OK> Warning 01: Outside of specification> Warning 02: Clipped to min> Warning 03: Clipped to max> Warning 04: Related parameters adjusted> Warning 05: Can’t set LVDS for this GPIO signal Warning 07: Coefficient may be inaccurate A/D clipping has occurred> Warning 08: Greater than 1% of coefficients have been clipped> Warning 09: Internal line rate inconsistent with readout time> Message Error 02: Unrecognized command> Error 03: Incorrect number of parameters> Error 04: Incorrect parameter value> Error 05: Command unavailable in this mode> SUCCESS Parameter accepted was outside of specified operating range (e.g. gain greater than ±10 dB of factory setting). Parameter was clipped to the current operating range. Use gcp to see value used. Parameter was clipped to the current operating range. Use gcp to see value used. Parameter was clipped to the current operating range. Use gcp to see value used. Input 3 and Output 3 cannot be set to use an LVDS signal. In the region of interest (ROI) greater than 6.251% single or 1% of averaged pixel values were zero or saturated. A FPN/PRNU has been calculated to be greater than the maximum allowable 511 (8). Description Command is not available in the current access level or it is not a valid command. This response returned for · Alpha received for numeric or vice versa · Not an element of the set of possible values. E.g., Baud Rate · Outside the range limit Command is valid at this level of access, but not effective. Eg line rate when in smart EXSYNC mode DALSA 03-032-10158-06

<strong>Spyder</strong> 3 <strong>GigE</strong> User’s <strong>Manual</strong><br />

103<br />

A5 Error Handling<br />

The following table lists warning and error messages and provides a description and<br />

possible cause. Warning messages are returned when the camera cannot meet the full<br />

value of the request; error messages are returned when the camera is unable to complete<br />

the request.<br />

Table 15: Warning and Error Messages<br />

Message<br />

Description<br />

OK><br />

Warning 01: Outside<br />

of specification><br />

Warning 02: Clipped<br />

to min><br />

Warning 03: Clipped<br />

to max><br />

Warning 04: Related<br />

parameters<br />

adjusted><br />

Warning 05: Can’t<br />

set LVDS for this<br />

GPIO signal<br />

Warning 07:<br />

Coefficient may be<br />

inaccurate A/D<br />

clipping has<br />

occurred><br />

Warning 08: Greater<br />

than 1% of<br />

coefficients have<br />

been clipped><br />

Warning 09: Internal<br />

line rate inconsistent<br />

with readout time><br />

Message<br />

Error 02:<br />

Unrecognized<br />

command><br />

Error 03: Incorrect<br />

number of<br />

parameters><br />

Error 04: Incorrect<br />

parameter value><br />

Error 05: Command<br />

unavailable in this<br />

mode><br />

SUCCESS<br />

Parameter accepted was outside of specified operating range (e.g. gain<br />

greater than ±10 dB of factory setting).<br />

Parameter was clipped to the current operating range. Use gcp to see<br />

value used.<br />

Parameter was clipped to the current operating range. Use gcp to see<br />

value used.<br />

Parameter was clipped to the current operating range. Use gcp to see<br />

value used.<br />

Input 3 and Output 3 cannot be set to use an LVDS signal.<br />

In the region of interest (ROI) greater than 6.251% single or 1% of<br />

averaged pixel values were zero or saturated.<br />

A FPN/PRNU has been calculated to be greater than the maximum<br />

allowable 511 (8).<br />

Description<br />

Command is not available in the current access level or it is not a valid<br />

command.<br />

This response returned for<br />

· Alpha received for numeric or vice versa<br />

· Not an element of the set of possible values. E.g., Baud Rate<br />

· Outside the range limit<br />

Command is valid at this level of access, but not effective. Eg line rate<br />

when in smart EXSYNC mode<br />

DALSA 03-032-10158-06

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!