Baumer FWX20c

Baumer FWX20c Baumer FWX20c

10.05.2014 Views

Technical Data FWX20c 4. Timing Operation Modes Trigger Mode: sequential operation parameter* n effective parameter* n+1 effective earliest possible Trigger earliest possible Trigger trigger t min t delay t min t delay exposure readout t readout(n) Frame n t readout(n+1) Frame n+1 flash t exp(n) t exp(n+1) Free Running Mode: sequential operation parameter* n effective parameter* n+1 effective exposure readout t readout(n) Frame n t readout(n+1) Frame n+1 flash t exp(n) t exp(n+1) * image parameter: exposure time offset global gain mode partial scan Technical specifications subject to change Baumer Optronic GmbH Badstrasse 30 DE-01454 Radeberg, Germany Phone +49 (0)3528 4386 0 Fax +49 (0)3528 4386 86 www.baumeroptronic.com Last change: 06.08.2007 Page 4 / 6 Version:TDS_FWX20c_v20e_070802.doc

Technical Data FWX20c 5. Housing 17 19 13,3 M2 / 6,3 Top view Front view 73 45 Side view 54,6 ±1,5 47,7 7±1,5 40 30,5 6,8 30 C-Mount Back view 4,5 56 30 30 7 23,7 23,7 4x M4 / 7 8x M4 / 7 6,8 6. Connectors / Electrical Interfaces IEEE1394a Pin Trigger / Flash Type: Lumberg RSMESD 4pin. IEEE 1394a 1: Power 2: GND 3: TPB- 4: TPB+ 5: TPA- 6: TPA+ 2 4 1 3 12V GND 1 TrigIN+ 2 TrigIN- 4 Flash 3 Trigger / Flash cable wires color *): 1 = brown 2 = white 3 = blue 4 = black *) shielded trigger / flash cable needs to be used and ordered separately End of Document Technical specifications subject to change Baumer Optronic GmbH Badstrasse 30 DE-01454 Radeberg, Germany Phone +49 (0)3528 4386 0 Fax +49 (0)3528 4386 86 www.baumeroptronic.com Last change: 06.08.2007 Page 5 / 6 Version:TDS_FWX20c_v20e_070802.doc

Technical Data <strong>FWX20c</strong><br />

4. Timing Operation Modes<br />

Trigger Mode: sequential operation<br />

parameter* n<br />

effective<br />

parameter* n+1<br />

effective<br />

earliest possible<br />

Trigger<br />

earliest possible<br />

Trigger<br />

trigger<br />

t min<br />

t delay<br />

t min<br />

t delay<br />

exposure<br />

readout<br />

t readout(n)<br />

Frame n<br />

t readout(n+1)<br />

Frame n+1<br />

flash<br />

t exp(n)<br />

t exp(n+1)<br />

Free Running Mode: sequential operation<br />

parameter* n<br />

effective<br />

parameter* n+1<br />

effective<br />

exposure<br />

readout<br />

t readout(n)<br />

Frame n<br />

t readout(n+1)<br />

Frame n+1<br />

flash<br />

t exp(n)<br />

t exp(n+1)<br />

* image parameter: exposure time<br />

offset<br />

global gain<br />

mode<br />

partial scan<br />

Technical specifications subject to change<br />

<strong>Baumer</strong> Optronic GmbH Badstrasse 30 DE-01454 Radeberg, Germany Phone +49 (0)3528 4386 0 Fax +49 (0)3528 4386 86 www.baumeroptronic.com<br />

Last change: 06.08.2007 Page 4 / 6 Version:TDS_<strong>FWX20c</strong>_v20e_070802.doc