<strong>Trillium</strong> User’s <strong>Manual</strong> 9<br />
Notes to Table 1.<br />
DN = Digital numbers (0-255); also known as gray levels.<br />
EC = Exposure control.<br />
1. <strong>Manual</strong> gain adjustment forces uncalibrated operation.<br />
2. With calibration off, using factory settings (these are separate from user<br />
defaults settings, both are set during factory calibration).<br />
3. With calibration on, using user default settings, using integrating sphere, and<br />
a 10°C drift from time of calibration.<br />
4. Tungsten halogen light source, 3200K bulb temp., and 750nm cutoff filter.<br />
5. Calibration off. Gain for each channel set to 2 (command sg 2, 2, 2).<br />
6. Deviation from ideal, from 10%-90% exposure. Measured after calibration,<br />
light intensity 120µW/cm 2 , 4kHz line rate. “Ideal” condition is based on line<br />
of best fit through 12 points of data.<br />
Figure 2.<br />
DALSA 03-32-10119-03