70 Trillium User’s Manual The second plot shows the limits for cc1/cc2 being able to calibrate the camera. The exposure time/temperature range for cc1/cc2 is greater than cc3. However, caution must be taken when calibrating at the lower line rates, as the effects of temperature drift will become greater. Plots for the blue channel only are shown, as the red/green channel offsets are lower due to their gain in the analog signal processing chain being only 60% of the blue channel. Blue Channel I nt egration Time Plots of O ffset+FPN /2 vs Tem per ature DN Offset 80 70 60 50 40 30 20 10 0 0 10 20 30 40 50 Tem p. C 3333usec 2000usec 1000usec 500usec 250usec 143usec 90.9usec "cc1/cc2" Limit Integration Time De-Rating Plots for the "cc1/cc2" Calibration Mode, Typical Gains Set to 2 Note: The de-rating curves are specified in integration time. Thus, low line rates can be used if the integration time is not exceeded. 03-32-10119-03 DALSA
Trillium User’s Manual 71 TRILLIUM USER'S MANUAL Appendix F: Revision History Revision Description 00 Manual release 01 Removed section 3.10 Increasing Sensitivity with Binning and removed the binning command from section C7. Binning Is not available in this camera. 02 Removed “Pending” from Appendix B: EMC Declaration of Conformity and updated declaration to new standards. 03 Removed all references to matched lenses. These are no longer available for this camera. Fixed incorrect gain range listed in section 1.3 from -6 to 12dB to 1 to 15.98dB and in section 3.7 from 0 to 15.98 to 1 to 15.98. Removed references to 0dB gain on pages 9, 69, and 70 and changed the value to 2 (the linear equivalent). DALSA 03-32-10119-03
- Page 19 and 20: Trillium User’s Manual 19 2.9 Tim
- Page 21 and 22: Trillium User’s Manual 21 C HAPTE
- Page 23 and 24: Trillium User’s Manual 23 Status
- Page 25 and 26: Trillium User’s Manual 25 3.8 Cal
- Page 27 and 28: Trillium User’s Manual 27 and the
- Page 29 and 30: Trillium User’s Manual 29 The pos
- Page 31 and 32: Trillium User’s Manual 31 Program
- Page 33 and 34: Trillium User’s Manual 33 These c
- Page 35 and 36: Trillium User’s Manual 35 3.14 Mo
- Page 37 and 38: Trillium User’s Manual 37 C HAPTE
- Page 39 and 40: Trillium User’s Manual 39 192.4 (
- Page 41 and 42: Trillium User’s Manual 41 Mount P
- Page 43 and 44: Trillium User’s Manual 43 Illumin
- Page 45 and 46: Trillium User’s Manual 45 C HAPTE
- Page 47 and 48: Trillium User’s Manual 47 T RILLI
- Page 49 and 50: Trillium User’s Manual 49 Unused
- Page 51 and 52: Trillium User’s Manual 51 T RILLI
- Page 53 and 54: Trillium User’s Manual 53 T RILLI
- Page 55 and 56: Trillium User’s Manual 55 C5. Exa
- Page 57 and 58: Trillium User’s Manual 57 C7. Com
- Page 59 and 60: Trillium User’s Manual 59 Command
- Page 61 and 62: Trillium User’s Manual 61 TRILLIU
- Page 63 and 64: Trillium User’s Manual 63 Note: A
- Page 65 and 66: Trillium User’s Manual 65 D4. Cal
- Page 67 and 68: Trillium User’s Manual 67 4. Exam
- Page 69: Trillium User’s Manual 69 TRILLIU
- Page 73 and 74: Trillium User’s Manual 73 INDEX A
70 <strong>Trillium</strong> User’s <strong>Manual</strong><br />
The second plot shows the limits for cc1/cc2 being able to calibrate the camera.<br />
The exposure time/temperature range for cc1/cc2 is greater than cc3. However,<br />
caution must be taken when calibrating at the lower line rates, as the effects of<br />
temperature drift will become greater. Plots for the blue channel only are shown,<br />
as the red/green channel offsets are lower due to their gain in the analog signal<br />
processing chain being only 60% of the blue channel.<br />
Blue Channel I nt egration Time Plots of<br />
O ffset+FPN /2 vs Tem per ature<br />
DN Offset<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
0<br />
0 10 20 30 40 50<br />
Tem p. C<br />
<strong>33</strong><strong>33</strong>usec<br />
2000usec<br />
1000usec<br />
500usec<br />
250usec<br />
143usec<br />
90.9usec<br />
"cc1/cc2" Limit<br />
Integration Time De-Rating Plots for the "cc1/cc2" Calibration Mode, Typical<br />
Gains Set to 2<br />
Note: The de-rating curves are specified in integration time. Thus, low line rates<br />
can be used if the integration time is not exceeded.<br />
03-32-10119-03 DALSA